Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: FIRST MARINE, LLC

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of FIRST MARINE, LLC in 354 HOLLINGER RD, CALVERT CITY, KY 42029 (NAICS 336611). OSHA activity number 347580110.

Watch First Marine, LLC — free Get an email when a new federal OSHA severe-injury report for First Marine, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
FIRST MARINE, LLC
Site address
354 HOLLINGER RD
City
CALVERT CITY
State
KY
ZIP
42029
Mailing
354 HOLLINGER RD, CALVERT CITY, KY 42029
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
18
Ownership type
A

4 citations on file for this inspection.

1910.304 B03 II A

Serious Gravity 10 3 instances 17 exposed
Issued
Abate by
Penalty
Initial $7098.00 · Current $4969.00 Reduced
29 CFR 1910.304(b)(3)(ii)(A): All 125-volt, single-phase, 15, 20 and 30-ampere receptacle outlets that are not part of the permanent wiring of the building or structure and that are in use by personnel did not have ground-fault circuit-interrupter protection for personnel.  a) Old Admin Barge, lower hull, East of carpentry shop: On or about June 25, 2024, and at times prior, the employer exposed employees to electrical shock hazards, in that GFCI equipped receptacles were removed and replaced with non-GFCI receptacles where sump pumps used to remove water from the barge are checked daily by employees.  b) Old Admin Barge, shed, North side of barge by dry dock:  On or about June 25, 2024, and at times prior, the employer exposed employees to electrical shock hazards, in that GFCI equipped receptacles were removed and replaced with non-GFCI receptacles where sump pumps used to remove water from the barge are checked daily by employees.  c) Old Admin Barge, lower hull, West side below material storage area:  On or about June 25, 2024, and at times prior, the employer exposed employees to electrical shock hazards, in that GFCI equipped receptacles were removed and replaced with non-GFCI receptacles where sump pumps used to remove water from the barge are checked daily by employees.
Recent events (2)
  • — I (S) $4968.6
  • — Z (S) $7098

1915.81 B01 IV

Repeat Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $12169.00 · Current $8518.00 Reduced
29 CFR 1915.81(b)(1)(iv):  The employer did not place each hose and cord in a location that would prevent injury to employees and damage to the hoses and cords.  a) Facility: On or about June 25th, 2024, and at times prior, the employer exposed employees to trip and fall hazards, in that welding hoses were placed over a stairway used to access the vessel in the drydock.  First Marine was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1915.81(b)(1)(iv), which was contained in OSHA inspection number 1292252, citation number 1, item number 5 and was affirmed as a final order on January 30, 2020, with respect to a workplace located at Calvert City, Kentucky.
Recent events (2)
  • — I (R) $8518.3
  • — Z (R) $12169

1910.305 G01 IV B

Other-than-serious 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $569.00 · Current $398.00 Reduced
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors:  a) Old Office barge, North-East side by metal shed:  On or about June 26, 2024, and at times prior, the employer exposed employees to electric shock hazards, in that an unprotected flexible cord was used to power a sump pump and was run under a wall and through a hole in the deck.
Recent events (2)
  • — I (O) $398.3
  • — Z (O) $569

1910.305 G02 III

Other-than-serious 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a) Old Admin barge, North-East side inside metal shed:  On or about June 26, 2024, and at times prior, the employer exposed employees to electric shock hazards, in that a flexible cord used to power a sump pump was not provided with strain relief to prevent tension from being transmitted to the joints or terminal screws.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View FIRST MARINE, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347580110.