Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OXFORD AIRPORT TECHNICAL SERVICES

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OXFORD AIRPORT TECHNICAL SERVICES in 3 BREWSTER RD, #A, NEWARK, NJ 07114 (NAICS 488119). OSHA activity number 347699944.

Watch Oxford Airport Technical Services — free Get an email when a new federal OSHA severe-injury report for Oxford Airport Technical Services is published. One employer, no account, unsubscribe in one click.
Site address
3 BREWSTER RD, #A
City
NEWARK
State
NJ
ZIP
07114
Mailing
3 BREWSTER RD, #B, NEWARK, NJ 07114
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
488119
Employees
70
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $13828.00 · Current $9680.00 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:(   A) Oxford Airport Technical Services - 3 Brewster Rd, #B NEWARK, NJ 07114 /Conveyor System - The employer did not develop lock out procedures to assist employees engaged in maintenance and or service activities. This condition exposed the employees to caught in hazards.   Incident occurred on August 12, 2024
Recent events (2)
  • — I (S) $9679.6
  • — Z (S) $13828

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $13828.00 · Current $9680.00 Reduced
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  A) Oxford Airport Technical Services - 3 Brewster Rd, #B NEWARK, NJ 07114 / Conveyor System - The employer failed to conduct periodic inspections of the energy control procedures and its authorized employees to ensure that the procedures and requirements were being followed.  Incident occurred August 12, 2024
Recent events (2)
  • — I (S) $9679.6
  • — Z (S) $13828

1910.147 D04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $16131.00 · Current $11292.00 Reduced
29 CFR  1910.147(d)(4)(i):Lockout or tagout devices were not affixed to each energy isolating device by authorized employees.  a) Oxford Airport Technical Services - 3 Brewster Rd, #B NEWARK, NJ 07114 - The employer did not ensure that the conveyor system was locked out prior to service being performed, causing employee to be injured by caught in hazard.  Incident occurred on August 12, 2024
Recent events (2)
  • — I (S) $11291.7
  • — Z (S) $16131

View OXFORD AIRPORT TECHNICAL SERVICES's full OSHA safety record →