2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: CHANCEY METALS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CHANCEY METALS, LLC in 5130 SUNBEAM ROAD, JACKSONVILLE, FL 32257 (NAICS 332996). OSHA activity number 348214297.

Watch Chancey Metals, LLC — free Get an email when a new federal OSHA severe-injury report for Chancey Metals, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CHANCEY METALS, LLC
Site address
5130 SUNBEAM ROAD
City
JACKSONVILLE
State
FL
ZIP
32257
Mailing
5130 SUNBEAM ROAD, JACKSONVILLE, FL 32257
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332996
Employees
35
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $7035.00 · Current $4221.00 Reduced
29 CFR  1910.147(c)(4)(i):  Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a.  At 5130 Sunbeam Road, Jacksonville, Florida:  On or about April 30, 2025, the employer exposed employees to caught-in and amputation hazards, in that procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees are conducting maintenance on machinery with more than one source of energy.
Recent events (2)
  • — I (O) $4221
  • — Z (S) $7035

1910.212 A01

Serious Gravity 10 6 instances 22 exposed
Issued
Penalty
Initial $9847.00 · Current $5908.00 Reduced
29 CFR  1910.212(a)(1):   One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a.  In Building 1 of the main shop area, at 5130 Sunbeam Road, Jacksonville, Florida:  On or about April 30, 2025, the employer exposed employees to caught-in and amputation hazards, in that the Willis Drill Press did not have a guard properly installed to provide protection of the point of operation and rotating parts.  b.  In Building 1 of the main shop area, at 5130 Sunbeam Road, Jacksonville, Florida:   On or about April 30, 2025, the employer exposed employees to amputation hazards, in that the GEKA-Ironworker did not have a guard properly installed on the punch to provide protection of the point of operation.  c.   In Building 1 of the main shop area, at 5130 Sunbeam Road, Jacksonville, Florida:   On or about April 30, 2025, the employer exposed employees to amputation hazards, in that the C-650 MNC Bandsaw did not have a guard properly installed on the unused portion of the blade to provide protection of the point of operation.  d.    In Building 1 of the main shop area, at 5130 Sunbeam Road, Jacksonville, Florida:  On or about April 30, 2025, the employer exposed employees to amputation hazards, in that the FMB Bandsaw Orion Model did not have a guard properly installed on the unused portion of the blade to provide protection of the point of operation.  e.    In Building 1 of the main shop area, at 5130 Sunbeam Road, Jacksonville, Florida:   On or about April 30, 2025, the employer exposed employees to amputation hazards, in that the FMB Bandsaw Antares Model did not have a guard properly installed on the unused portion of the blade to provide protection of the point of operation.  f.    In Building 2, at 5130 Sunbeam Road, Jacksonville, Florida:  On or about April 30, 2025, the employer exposed employees to amputation hazards, in that the FMB Bandsaw did not have a guard properly installed on the unused portion of the blade to provide protection of the point of operation.
Recent events (2)
  • — I (S) $5908.2
  • — Z (S) $9847

1910.303 G01 VII

Serious Gravity 5 1 instance 22 exposed
Issued
Penalty
Initial $5627.00 · Current $3376.00 Reduced
29 CFR  1910.303(g)(1)(vii):   Switchboards, panel boards, and distribution boards installed for the control of light and power circuits, and motor control centers were not located in dedicated spaces and protected from damage:  a.  In Building 1 of the main shop area, at 5130 Sunbeam Road, Jacksonville, Florida:  On or about April 30, 2025, the employer exposed employees to electrical hazards, in that panel boards for the control of the fabrication shop's lights and equipment were blocked and the doors were being used as coat racks.
Recent events (2)
  • — I (S) $3376.2
  • — Z (S) $5627

1910.22 A01

Other-than-serious 1 instance 22 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.22(a)(1):   The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition:  a.  In Building 1 of the main shop area, at 5130 Sunbeam Road, Jacksonville, Florida:   On or about April 30, 2025, the employer exposed employees to fire and electrical hazards, in that passageways near machinery work areas were being used as break areas with appliances and not kept clean and orderly for employees.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 1 instance 22 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(g)(2)(iii):   Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  a.  In Building 1 of the main shop area, at 5130 Sunbeam Road, Jacksonville, Florida:  On or about April 30, 2025, the employer exposed employees to electrical hazards, in that electrical wiring on the FMB Bandsaw Orion Model was not connected to devices and fittings so that tension would not be transmitted to joints which could cause resistance.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View CHANCEY METALS, LLC's full OSHA safety record →