SAINT MARYS, PA —
OSHA Inspection: AMPHENOL THERMOMETRICS INC. -SAINT MARYS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AMPHENOL THERMOMETRICS INC. -SAINT MARYS in 967 WINDFALL ROAD, SAINT MARYS, PA 15857 (NAICS 334416). OSHA activity number 348244849.
Where did this inspection happen?
- Establishment
- AMPHENOL THERMOMETRICS INC. -SAINT MARYS
- Site address
- 967 WINDFALL ROAD
- City
- SAINT MARYS
- State
- PA
- ZIP
- 15857
- Mailing
- 967 WINDFALL ROAD, SAINT MARYS, PA 15857
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334416
- Employees
- 300
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $12059.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): A.) Amphenol Thermometrics Inc. -Saint Marys, On or about 5/7/25 and times prior thereto: Employees did not lockout prior to setting up equipment including but not limited to Machine 3588. While setting up 3588 the table rotated and an employee's hand was caught between the table and the airline resulting in a laceration. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (S) $12059
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i):The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: A.) Amphenol Thermometrics Inc. -Saint Marys, On or about 5/7/25 and times prior thereto: Employees designated as affected are performing authorized employee tasks and have not received authorized training. Tasks include but are not limited to setting up equipment. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I C
- Issued
- Abate by
- Penalty
- Initial $12059.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C):Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected: A.) Amphenol Thermometrics Inc. -Saint Marys, On or about 5/7/25 and times prior thereto: Employees perform service and maintenance on equipment including, but not limited to, Machine 3588. Annual periodic inspections of the lockout tagout procedures did not include a review with authorized employees about their responsibilities under the energy control procedure being inspected. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $3000
- — Z (S) $12059
1910.147 C06 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(ii):The certification did not identify the machine or equipment on which the energy control procedure was being utilized: A.) Amphenol Thermometrics Inc. -Saint Marys, On or about 5/13/25 and times prior thereto: Employees at the facility periodically perform service and maintenance tasks to equipment. The 2024 Periodic Inspection did not identify the machine or equipment on which the energy control procedure was being utilized. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $12059.00 · Current $10000.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: A.) Amphenol Thermometrics Inc. -Saint Marys, On or about 5/13/25 and times prior thereto: Machine 3588 did not have guarding in place to prevent employees from contacting moving parts. A section of the plexiglass about 5 feet above the ground was removed. Employees can reach through the missing section of guarding to contact moving parts. B.)Amphenol Thermometrics Inc. -Saint Marys, On or about 5/7/25 and times prior thereto: Employees who operate the 3558 were exposed to rotating parts and caught between hazards when jogging the rotary table during set up. The machine was not outfitted with effective alternative safeguarding measures during set up that kept employees away from the danger zone. During set up of 3558 the table rotated, and an employee's hand was caught between the table and the airline resulting in a laceration. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement
Recent events (2)
- — I (S) $10000
- — Z (S) $12059
1910.147 E03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(e)(3):29 CFR 1910.147(e)(3): When the authorized employee who applied the lockout or tagout device was not available to remove it, and the device removal is completed under the direction of the employer, specific procedures and training were not developed, documented and incorporated into the employer's energy control program: A.) Amphenol Thermometrics Inc. -Saint Marys, On or about 5/7/25 and times prior thereto: In the written Lockout/Tagout Plan, the procedure for the removal of locks left on equipment by someone other than the authorized employee who applied it, did not include detailed workplace specific procedures to: 1. Verify that the authorized employee who applied the device is not in the facility 2. Document how the authorized employee who applied the device will be contacted 3. Ensure that the authorized employee whose device was removed has been informed of the removal before resuming work ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 334416)
BLAND, VA—2026-03-02
HITACHI ENERGY USA INC.
RINCON, GA—2025-11-21
CARAVELS, LLC
GERMANTOWN, WI—2025-11-20
TCI, LLC.
PALO ALTO, CA—2025-06-25
PEARSON ELECTRONICS INC.
RINCON, GA—2025-06-09
CARAVELS, LLC
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348244849.