Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: AMERICAN BOA, INCORPORATED

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AMERICAN BOA, INCORPORATED in 1485 REDI RD, CUMMING, GA 30040 (NAICS 332919). OSHA activity number 348449851.

Watch American BOA, Incorporated — free Get an email when a new federal OSHA severe-injury report for American BOA, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
1485 REDI RD
City
CUMMING
State
GA
ZIP
30040
Mailing
1485 REDI RD, CUMMING, GA 30040
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332919
Employees
140
Ownership type
A

11 citations on file for this inspection.

1910.184 C14

Other-than-serious Gravity 5 3 instances 6 exposed
Issued
Penalty
Initial $7235.00 · Current $4416.00 Reduced
29 CFR 1910.184(c)(14): The employer allowed for slings without affixed and legible identification markings to be used:  a) Machine shop: On or about 8/19/2025, employees were exposed to crush hazards during activities including, but not limited to, moving bar stock because an 80-inch nylon endless loop sling was in use without legible data tags to inform the user of weight limitations and authorized lifting configurations.  b) Machine shop: On or about 8/19/2025, employees were exposed to crush hazards during activities including, but not limited to, moving bar stock because a 107-inch nylon endless loop sling was in use without legible data tags to inform the user of weight limitations and authorized lifting configurations.  c) Machine shop: On or about 8/19/2025, employees were exposed to crush hazards during activities including, but not limited to, moving bar stock because a 6-foot nylon lift sling was in use without legible data tags to inform the user of weight limitations and authorized lifting configurations.
Recent events (2)
  • — I (O) $4415.5
  • — Z (S) $7235

1910.184 D

Other-than-serious Gravity 1 1 instance 6 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.184(d): Each day before being used, the sling and all fastenings and attachments were not being inspected for damage or defects by a competent person designated by the employer:   a) Machine shop: On or about 8/19/2025, employees were exposed to struck-by hazards during material handling operations, including but not limited to the movement of bar stock. The employer did not ensure that a competent person inspected slings and their attachments for damage or defects prior to daily use, as required. The absence of a sling inspection program increased the risk of equipment failure during lifting operations, potentially resulting in dropped loads and serious injury to employees working nearby.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $10641.00 · Current $6119.00 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s):   a) Aeronautics Shop: On or about 8/19/2025, employees were exposed to struck-by, caught-in, and burn hazards during welding operations because the foot pedals used to control welding equipment were not equipped with guards to prevent accidental actuation, which could result in unintended activation of welding arcs or mechanical movement.
Recent events (2)
  • — I (S) $6118.5
  • — Z (S) $10641

1910.212 A03

Serious Gravity 5 7 instances 6 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.212(a)(3): Point of operation guarding were not provided:  a) Machine shop, Victor 1640-B Lathe - On or about 8/19/2025, employees performing cutting operations were exposed to amputation hazards because the rotating chuck was not guarded.  b) Machine shop, MSC 14-50G Lathe - On or about 8/19/2025, employees performing cutting operations were exposed to amputation hazards because the rotating chuck was not guarded.  c) Machine shop, Sharp 1660LV Lathe - On or about 8/19/2025, employees performing cutting operations were exposed to amputation hazards because the rotating chuck was not guarded.  d) Machine shop, Bridgeport Milling Machine - On or about 8/19/2025, employees performing cutting operations were exposed to amputation hazards because the rotating chuck was not guarded.  e) Machine shop, Seiki-XL Milling Machine - On or about 8/19/2025, employees performing cutting operations were exposed to amputation hazards because the rotating chuck was not guarded.  f) Machine shop, DeWalt DW756 Pedestal Grinder - On or about 8/19/2025, employees performing grinding operations were exposed to amputation and struck-by hazards because the left and right side guards were not installed, exposing the rotating stones.  g) Machine shop, Pedestal Grinder with Belt Sander Attachment - On or about 8/19/2025, employees performing grinding operations were exposed to amputation and struck-by hazards because the belt side shield was not installed, exposing the rotating parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 B

Deleted Serious Gravity 1 4 instances 6 exposed
Issued
Penalty
Initial $6384.00 · Current $0.00 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:   a) Machine shop - DeWalt DW756 pedestal grinder, Serial Number 2014-26-YL-105578: On or about 8/19/2025, employees performing grinding operations were exposed to struck-by hazards because the pedestal was not permanently affixed to the floor.  b) Machine shop - Baldor 248-1811D pedestal grinder: On or about 8/19/2025, employees performing grinding operations were exposed to struck-by hazards because the pedestal was not permanently affixed to the floor.  c) Machine shop - Baldor 248-1811D pedestal grinder with belt sander attachment: On or about 8/19/2025, employees performing grinding operations were exposed to struck-by hazards because the pedestal was not permanently affixed to the floor.  d) Machine shop - DeWalt DW756 pedestal grinder, Serial Number 2014-26-YL-105581: On or about 8/19/2025, employees performing grinding operations were exposed to struck-by hazards because the pedestal was not permanently affixed to the floor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6384

1910.215 A04

Deleted Serious Gravity 5 2 instances 6 exposed
Issued
Penalty
Initial $10641.00 · Current $0.00 Reduced
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work:  a) Machine shop: Baldor 248-1811D pedestal grinder with belt sander attachment: On or about 8/19/2025, employees performing grinding operations were exposed to struck-by hazards because the left bench rest was not properly adjusted to the required 1/8-inch clearance; it measured approximately 1/2-inch.  b) Machine shop: DeWalt DW756 pedestal grinder, Serial Number 2014-26-YL-105581: On or about 8/19/2025, employees performing grinding operations were exposed to struck-by hazards because the left and right bench rests were not properly adjusted to the required 1/8-inch clearance; the left measured approximately 1 inch and the right measured approximately 3/4-inch.
Recent events (2)
  • — I (S) $0
  • — Z (S) $10641

1910.215 B09

Other-than-serious Gravity 5 2 instances 6 exposed
Issued
Penalty
Initial $0.00 · Current $6119.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  a) Machine shop: Baldor 248-1811D pedestal grinder with belt sander attachment: On or about 8/19/2025, employees performing grinding operations were exposed to struck-by hazards because the left tongue guard was not properly adjusted to the required 1/4-inch clearance; it measured approximately 2 1/2 inches.  b) Machine shop: DeWalt DW756 pedestal grinder, Serial Number 2014-26-YL-105581: On or about 8/19/2025, employees performing grinding operations were exposed to struck-by hazards because the left and right tongue guards were not properly adjusted to the required 1/4-inch clearance; the left measured approximately 1/2 inch and the right measured approximately 1 1/4 inches.
Recent events (2)
  • — I (O) $6118.5
  • — Z (S) $0

1910.215 A02

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $10641.00 · Current $0.00 Reduced
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections:   a) Machine shop, DeWalt, DW756, pedestal grinder, Serial Number 2014-26-YL105581: On or about 8/19/2025, employees performing grinding operations were exposed to struck-by hazards, in that the left and right safety guards were missing, exposing the rotating stones, spindle ends, nuts, & flange projections.
Recent events (2)
  • — I (S) $0
  • — Z (S) $10641

1910.219 E01

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $0.00 · Current $6119.00
29 CFR 1910.219(e)(1): Horizontal belts 42 inches or less from the floor, were not fully enclosed in accordance with paragraphs (m) and (o) of this section.   a) Machine shop, Baldor, 248-1811D, pedestal grinder: On or about 8/19/2025, employees performing grinding operations were exposed to struck-by hazards in that the right safety guard was missing, exposing the rotating pulleys, spindle ends, nuts, & flange projections.
Recent events (2)
  • — I (S) $6118.5
  • — Z (S) $0

1910.303 B02

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Maintenance Department, Fuse testing bench: On or about 8/19/2025, employees were exposed to electrical hazards because metallic quad boxes, which were listed and labeled for fixed mounting, were used as pendants at the ends of flexible cords and were not securely mounted to a stable surface as required by their listing and labeling.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B07 I

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $5426.00 · Current $2713.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Maintenance Department, Fuse testing bench: On or about 8/19/2025, employees were exposed to potential electrical hazards because metallic quad boxes, which were listed and labeled for fixed mounting, were used as pendants at the ends of flexible cords and were not securely mounted to a stable surface as required by their listing and labeling.
Recent events (2)
  • — I (O) $2713
  • — Z (O) $5426

View AMERICAN BOA, INCORPORATED's full OSHA safety record →