STONY POINT, NY —
OSHA Inspection: J WAMAN CONSTRUCTION, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of J WAMAN CONSTRUCTION, INC. in 24 JOHNSON DR, STONY POINT, NY 10980 (NAICS 238160). OSHA activity number 348458407.
Where did this inspection happen?
- Establishment
- J WAMAN CONSTRUCTION, INC.
- Site address
- 24 JOHNSON DR
- City
- STONY POINT
- State
- NY
- ZIP
- 10980
- Mailing
- 15 EAST CASTLE AVENUE, SPRING VALLEY, NY 10977
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.501 B04 I
- Issued
- Penalty
- Initial $4965.00 · Current $4965.00
General-duty citation text
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. On or about August 21st, 2025 Location: 24 Johnson Dr, Stony Point, NY 10980 a) Employees exposed to a fall of approximately 13 ft while working on pitched roof without skylight covers.
Recent events (1)
- — Z (S) $4965
1926.502 D09
- Issued
- Penalty
- Initial $4965.00 · Current $4965.00
General-duty citation text
29 CFR 1926.502(d)(9): Lanyards and/or vertical lifelines did not have a minimum breaking strength of 5,000 pounds (22.2 kN): On or about August 21st, 2025 Location: 24 Johnson Dr, Stony Point, NY 10980 a) An employee was exposed to an approximately 20 ft fall while working on a 6:12 (rise:run) pitched roof with a lanyard that did not resist 5,000 pounds.
Recent events (1)
- — Z (S) $4965
1926.502 D15
- Issued
- Penalty
- Initial $4965.00 · Current $4965.00
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person. On or about August 21st, 2025 Location: 24 Johnson Dr, Stony Point, NY 10980 a) Employees were exposed to approximately 20 ft fall while working on a 6:12 (rise:run) pitched roof with anchor plates installed sideways and without the necessary number of nails per plate. b) Employees were exposed to approximately 20 ft fall while working on a 6:12 (rise:run) pitched roof were connected to the same anchor plate.
Recent events (1)
- — Z (S) $4965
1926.502 D17
- Issued
- Penalty
- Initial $4256.00 · Current $4256.00
General-duty citation text
29 CFR 1926.502(d)(17): The attachment point of the body belt was not located in the center of the wearer's back. The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head. On or about August 21st, 2025 Location: 24 Johnson Dr, Stony Point, NY 10980 a) Employees were exposed to injuries while attaching the positioning device of the fall protection system between their legs.
Recent events (1)
- — Z (S) $4256
1926.502 D21
- Issued
- Penalty
- Initial $4965.00 · Current $4965.00
General-duty citation text
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service: On or about August 21st, 2025 Location: 24 Johnson Dr, Stony Point, NY 10980 a) Employee was exposed to an approximately 20 ft fall while working on a 6:12 (rise:run) pitched roof while using damaged personal fall arrest system.
Recent events (1)
- — Z (S) $4965
1926.1053 B16
- Issued
- Penalty
- Initial $4256.00 · Current $4256.00
General-duty citation text
29 CFR 1926.1053(b)(16):Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired.( On or about August 1st, 2023 Location: 8 Hobe St, West Nyack, NY 10994 a) Employees accessed the roof through an extension ladder that had missing lanyard.
Recent events (1)
- — Z (S) $4256
More inspections at J WAMAN CONSTRUCTION, INC.
CLIFTON, NJ—2025-03-13 00:00:00
J WAMAN CONSTRUCTION, INC.
TEANECK, NJ—2023-05-16 00:00:00
J WAMAN CONSTRUCTION, INC.
View J WAMAN CONSTRUCTION, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
PORTLAND, OR—2026-07-17 00:00:00
317744797 - JBC ROOFING LLC
MERIDIAN, ID—2026-07-17 00:00:00
COBRA'S ROOFING LLC
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
BRADLEY, IL—2026-07-16 00:00:00
JUAN CRUZ DBA ROOFBOYS LLC
PONCE INLET, FL—2026-07-16 00:00:00
RESOLUTE ROOFING LLC
More inspections in NY
LIBERTY, NY—2026-07-17 00:00:00
SULLIVAN COUNTY CARE CENTER AT SUNSET LAKE
NEW YORK, NY—2026-07-17 00:00:00
VERGARA ELECTRICAL LLC
ONEONTA, NY—2026-07-17 00:00:00
APPLE CONVERTING, INC.
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
SYRACUSE, NY—2026-07-17 00:00:00
CRANESVILLE BLOCK CO., INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348458407.