MUNDELEIN, IL —
OSHA Inspection: AMCOR FLEXIBLES INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AMCOR FLEXIBLES INC. in 1919 BUTTERFIELD ROAD, MUNDELEIN, IL 60060 (NAICS 326112). OSHA activity number 348723388.
Where did this inspection happen?
- Establishment
- AMCOR FLEXIBLES INC.
- Site address
- 1919 BUTTERFIELD ROAD
- City
- MUNDELEIN
- State
- IL
- ZIP
- 60060
- Mailing
- 1919 BUTTERFIELD ROAD, MUNDELEIN, IL 60060
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326112
- Employees
- 220
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $10854.00 · Current $10854.00
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) Line 501: On or about January 23, 2026, January 26, 2026 and January27, 2026, a laminator operator was exposed to machine hazards associated with moving parts while wiping and scraping adhesive (reactive glue) from laminating rolls on Line 501 when the film dipped too far into the adhesive spreading it across the line. The employer did not implement energy control application steps such as but not limited to lockout tagout when performing these tasks [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving dissipation machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — C (S) $10854
- — Z (S) $10854
More inspections at AMCOR FLEXIBLES INC.
MUNDELEIN, IL—2025-05-14
AMCOR FLEXIBLES INC.
COMMERCE, CA—2021-11-16 00:00:00
AMCOR FLEXIBLES INC
ASHEVILLE, NC—2012-05-22 00:00:00
AMCOR FLEXIBLES INC.
View AMCOR FLEXIBLES INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326112)
SUWANEE, GA—2026-06-25
ROSSINI NORTH AMERICA, LLC
ORANGEBURG, SC—2026-06-17
77529 - INDEVCO INC OF NORTH AMERICA
CONOVER, NC—2026-05-13
161214 - PREGIS PROTECTIVE FILMS - COATINGS, INC.
BIOLA, CA—2026-05-07
POLYCELL PACKAGING CORPORATION
RHINELANDER, WI—2026-05-06
PRINTPACK INC.
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348723388.