PHILLIPS, WI —
OSHA Inspection: PHILLIPS-MEDISIZE, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PHILLIPS-MEDISIZE, LLC in 1156 S. AIRPORT RD., PHILLIPS, WI 54555 (NAICS 326199). OSHA activity number 348756172.
Where did this inspection happen?
- Establishment
- PHILLIPS-MEDISIZE, LLC
- Site address
- 1156 S. AIRPORT RD.
- City
- PHILLIPS
- State
- WI
- ZIP
- 54555
- Mailing
- 1156 S. AIRPORT RD., PHILLIPS, WI 54555
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 160
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 D03
- Issued
- Abate by
- Penalty
- Initial $10640.00 · Current $8512.00 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Press 4-2, secondary finishing station; On or about February 11, 2026, and dates prior, the service and maintenance tasks of replacing tape rolls and/or clearing jammed tape from the tape cutter/outfeed mechanism was performed on the Start brand ZCM 1000 electronic tape dispenser (serial number 142467) without the equipment being unplugged to isolate it from the energy source.
Recent events (2)
- — I (O) $8512
- — Z (S) $10640
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $10640.00 · Current $8512.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Press 4-2, secondary finishing station; On or about February 11, 2026, and dates prior, employees were exposed to improperly guarded cutting blades on the Start brand ZCM 1000 electronic tape dispenser (serial number 142467) as the tape cutter outfeed opening was large enough to allow for employees to have their fingers within the zone of danger during operating cycles.
Recent events (2)
- — I (O) $8512
- — Z (S) $10640
More inspections in this industry (NAICS 326199)
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
PETALUMA, CA—2026-07-10
LABCON NORTH AMERICA
KEEWATIN, MN—2026-07-09
111565 - TACKLE TAMER PRODUCTS INC
EAST FLAT ROCK, NC—2026-07-09
161517 - ELKAMET, INC.
LANESBOROUGH, MA—2026-07-08
LANSEN MOLD CO., INC.
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source