SAN DIEGO, CA —
OSHA Inspection: DEPT. OF DEFENSE - USMC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DEPT. OF DEFENSE - USMC in COMMUNITY CENTER, BOWLING ALLEY 3800 CHOSIN AVE, BUILDING 590, SAN DIEGO, CA 92140 (NAICS 561210). OSHA activity number 348781949.
Where did this inspection happen?
- Establishment
- DEPT. OF DEFENSE - USMC
- Site address
- COMMUNITY CENTER, BOWLING ALLEY 3800 CHOSIN AVE, BUILDING 590
- City
- SAN DIEGO
- State
- CA
- ZIP
- 92140
- Mailing
- 3800 CHOSIN AVE BLDG 5E, SAN DIEGO, CA 92140
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561210
- Employees
- 268
- Ownership type
- D
Citations
7 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazards created by in-going nip points, rotating parts, and/or flying chips and sparks: Mechanic Room: On or about March 3, 2026, the employees operated the Bauer Drill Press (Model: 22201E-B and Serial: 354132318) that did not contain a method of guarding around the rotating chuck.
Recent events (1)
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Arcade: On or about March 3, 2026, two MotoGP Motorcycle Games (Serial No. 4812) were plugged into a NXT Technologies surge protector (Model: NX54312) instead of being plugged directly into a nearby wall outlet.
Recent events (1)
- — Z (S) $0
1904.40 A
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours. Bowling Alley: The OSHA 300 logs and OSHA 300A for the past three years, were not provided upon request within the same business day.
Recent events (1)
- — Z (O) $0
1910.37 A03
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed. Mechanic Room: On or about March 3, 2026, and at times prior to, a fan, broom and dustpan and some chairs were stored along the path of the exit route leading to the nearest exit door.
Recent events (1)
- — Z (O) $0
1910.106 D03 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.106(d)(3)(ii): Flammable liquid storage cabinet(s) were not labeled in conspicuous lettering, "Flammable - Keep Fire Away" Back of the lane area, pin retrieval: On or about March 3, 2026, employees utilized various flammable chemicals and stored them in a secure location such as the yellow flammable cabinet without it being labeled as such.
Recent events (1)
- — Z (O) $0
1910.151 B
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.151(b): First aid supplies approved by a consulting physician were not readily available Mechanic room: On or about March 3, 2026, employees conducted repair tasks with the pinsetter machine had a first aid kit with an antiseptic spray and burn spray that were expired.
Recent events (1)
- — Z (O) $0
1910.1200 F06 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(6)(ii):The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with product identifier and words, pictures, symbols, or combination thereof, which provided at least general information regarding the hazards of the chemicals: Bowling Alley: On or about March 3, 2026, the employees cleaned bowling lanes and windows using secondary bottles, without a secondary label attached displaying the contents and hazards associated with the following chemicals: a) WP-2000 Lane Cleaner b) Ecolab Windex Glass Cleaner
Recent events (1)
- — Z (O) $0
More inspections at DEPT. OF DEFENSE - USMC
TWENTYNINE PALMS MCB, CA—2026-06-24
DEPT. OF DEFENSE - USMC
TWENTYNINE PALMS MCB, CA—2026-06-24
DEPT. OF DEFENSE - USMC
TWENTYNINE PALMS MCB, CA—2026-06-23
DEPT. OF DEFENSE - USMC
TWENTYNINE PALMS MCB, CA—2026-06-23
DEPT. OF DEFENSE - USMC
OCEANSIDE, CA—2026-04-03
DEPT. OF DEFENSE - USMC
View DEPT. OF DEFENSE - USMC's full OSHA safety record →
More inspections in this industry (NAICS 561210)
DEDHAM, MA—2026-07-08
DEDHAM FACILITIES DEPARTMENT
HACKETTSTOWN, NJ—2026-07-07
TOWN OF HACKETTSTOWN DEPARTMENT OF PUBLIC WORKS
SALEM, VA—2026-07-02
ROANOKE COUNTY PUBLIC SCHOOLS
PEMBERTON, NJ—2026-07-02
TOWNSHIP OF PEMBERTON DPW
NEW GRETNA, NJ—2026-07-01
BASS RIVER TOWNSHIP DPW
More inspections in CA
IRVINE, CA—2026-07-13
SNEARY CONSTRUCTION, INC.
IRVINE, CA—2026-07-13
KUKBO DESIGN USA LLC
ENCINITAS, CA—2026-07-13
LOU RIDDLE CONSTRUCTION
CANYON COUNTRY, CA—2026-07-13
COLLEGE OF THE CANYONS
LINDSAY, CA—2026-07-13
NATIONAL DIVERSIFIED SALES, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348781949.