Struck by falling object or equipment, unspecified · Crushing injuries
At a glance
Federal OSHA recorded a severe workplace injury
at ZION NATIONAL PARK, STATE ROUTE 9, SPRINGDALE, UTAH 84767
on — Crushing injuries, affecting the hand(s), unspecified.
Final narrative
An employee had his left hand crushed while using a crow bar to help set a concrete sewage distribution box.
HospitalizedHand(s), unspecifiedTanks, bins, vats-nonconfined space
An employee was performing a search and rescue operation to find a missing hiker when he tripped on the trail and struck a rock. The employee was hospitalized with a broken femur.
An employee was stepping out of an RV to answer a park visitor's question when she fell from the RV steps and suffered deep bruising to her pelvis and hip.
An employee was unloading 30-foot 2-inch barrels from a pan holding about 20 barrels. The barrels tipped over, striking and breaking both of the employee's lower legs.
An employee was in a sandblasting area, preparing the surface of a plate heat exchanger frame for painting. The frame fell on the employee, who suffered fractures to vertebrae, the neck, pelvis, and rib cage; and punctured lungs.
After completing a fitness test, an employee experienced lower leg pain and an inability to walk. The employee was hospitalized for compartment syndrome in both legs.
An employee was cutting up a large tree that had blown down on a rocky ledge on a hill. He began cutting on the uphill side of the tree, but due to obstructions he had to move to the downhill side. The tree separated from its 7-foot root ball, which started sliding toward him. While attempting to get out of the way, he tripped and fell to the ground, striking his head on an unknown object. As the root ball continued to move toward the employee, he made it below the level of the rock ledge. The root ball rolled over when it reached the ledge and pinned the employee's lower leg, and broke his fibula. He also suffered scrapes and bruises from the fall.
An employee was walking on a trail in a national park and stepped onto an angled and flat slab of granite when her ankle rolled and her weight shifted, but she did not fall. She was hospitalized with a fractured tibia and fibula and a dislocated ankle.
An employee was offroad, looking for a lost hiker. The employee fell off a canyon rim edge and landed on rimrock 5 or 6 feet below, suffering a separated shoulder and a head injury that required stitches. The employee was hospitalized.
An employee was preparing to conduct maintenance on a riding lawn mower and lifted the mower deck upward to its vertical position with assistance from another employee. A third employee pulled a locking pin, causing the front wheel mount to move forward into the cab. The cab entrance hand hold crushed the little fingers on the injured employee's hands. The employee was hospitalized and required surgical amputation of the right little finger to the second joint, as well as debriding and stitches to the left little finger.
An employee was on a four-step work stand while sanding an area of an aircraft. He was climbing down the work stand when he tripped over an air hose and fell to the level below, resulting in a fractured femur.
An employee was scanning the placards of pallets of mail bundles when a forklift approached from the opposite side and began lowering and pushing his pallet load forward. It struck the pallet the employee was working on, causing it to shift and strike her. She fell to the ground and sustained a left hip fracture that required surgery.
An X-ray machine had lost power and an employee went to replace the power supply. While replacing a cable on the power supply assembly, the employee's right hand contacted the grounding terminals coming out of the back of the power supply assembly and they received an electric shock. The employee was hospitalized.
An employee was servicing equipment and had disconnected a 4-inch line. A proportional control air valve on the equipment actuated, releasing a large volume of air at 99 psi into the 4-inch braided stainless steel line hanging down from the valve. The sudden release of pressure caused the line to whip and strike the employee's face. He was hospitalized due to an orbital bone fracture requiring surgery. The equipment was not locked out/tagged out at the time.
An employee was performing janitorial duties and carrying bathroom supplies when he slipped on a guardrail mounting post and fell on his side. The employee's hip was fractured and required surgery.