Fire, unspecified · Second degree heat (thermal) burns
At a glance
Federal OSHA recorded a severe workplace injury
at Renewable Energy Group, Inc., 36187 Hwy 30, GEISMAR, LOUISIANA 70734
on — Second degree heat (thermal) burns, affecting the multiple body parts, n.e.c..
Watch Renewable Energy Group, Inc. — freeGet an email when a new federal OSHA severe-injury report for Renewable Energy Group, Inc. is published. One employer, no account, unsubscribe in one click.
Final narrative
Two employees were hospitalized due to a fire at the manufacturing facility. They suffered first and second degree burns on the neck, back, and hands.
HospitalizedMultiple body parts, n.e.c.Nonclassifiable
More severe injuries at Renewable Energy Group, Inc.
An employee was operating a caustic flush and adding potassium hydroxide to water when the solution splashed him, causing chemical burns to his arm, face, and head. He was hospitalized.
An employee was performing oversight for the welding of a pipeline launcher door on a construction project. Two welders were performing arc welding, one on the interior diameter of the pipeline launcher door, and the other on the outside diameter of the launcher door when a flash fire occurred. The injured employee sustained first- and second-degree burns to the face, neck, back, and hands.
While on a scissor lift, an employee was grinding a steel pipe. Sparks from the grinder ignited some nearby rags that had been used to apply coating treatments to the pipe. This fire subsequently ignited the employee's clothing. The employee sustained burns to approximately 46% of their body and was hospitalized.
An employee was working in an area where another company was also working. The other company's employees were using an electric hydraulic pump to remove the bolts of the frac valve. The wiring of the torque wrench and pump unit were then charred and a flash fire occurred. The employee sustained second-degree burns to their face and neck.
On October 17, 2023, an employee was at a sink while using a solvent to unclog a vacuum trap dip tube that contained solids from pinacolborane distillation. During this process, the sink caught on fire and the solvent bottle containing tert-butyl methyl ether fell into the burning sink. The employee attempted to remove the solvent bottle which also caught on fire and suffered burns to their neck and left hand.
An employee was under a railcar cleaning up dust with a vacuum hose. The hose caused a spark that caused a flash fire that ignited the employee's clothing. The employee sustained second- and third-degree burns over 83% of his body.
More severe injuries in this industry (NAICS 325998)
An employee was walking on a sidewalk and stubbed his toe on an elevated portion of concrete, causing him to trip and fall. The employee's right knee was dislocated.
An employee was removing a hose from a chemical tank after filling the tank with hexamethylenediamine (HMD). He checked the line to ensure that the hose was clear, then disconnected the hose at the connection. Residual chemical sprayed onto his face, causing a second-degree burn. He was hospitalized.
Two employees were moving a railcar (plastic pellet hopper car) using a mobile railcar mover. One employee was the engineer in control of the railcar mover and the injured employee was a switchman. The railcar mover went forward and the hopper railcar struck the injured employee, resulting in a severe crushing injury to the employee's right arm.
An employee was opening a filter housing in the potassium chloride production area and got sprayed with a hot solution of potassium chloride brine. The employee sustained thermal burns to their right hand and legs.
An employee was performing maintenance on a guillotine cutter machine. As the employee was placing a pin in the machine, his left middle fingertip was caught, resulting in a partial amputation to the finger. The machine was not locked out at the time.
A driver was exiting his vehicle outside the plant gate when his foot slipped on the top step of the truck. He fell to the ground, landed on his left hip and elbow. The employee was hospitalized with a fractured hip/femur.
A security employee was responding to an urgent call from staff regarding a violent patient. The employee tripped and fell on the floor outside of the stairwell. The employee sustained a closed head injury, contusion of the cerebrum without loss of consciousness, and a closed fracture of the distal end of the right radius.
A temporary employee was testing an electrical starter motor. He was placing tape on the starter while the breaker was not engaged, but the starter sent an arc flash that burned his hands and stomach.
An employee was walking on a sidewalk and stubbed his toe on an elevated portion of concrete, causing him to trip and fall. The employee's right knee was dislocated.