Nonclassifiable · Loss of consciousness-not heat related
At a glance
Federal OSHA recorded a severe workplace injury
at Kinder Morgan, 1001 Louisiana, HOUSTON, TEXAS 77002
on — Loss of consciousness-not heat related, affecting the bODY SYSTEMS.
Final narrative
An employee was talking and then slumped over in his chair. He was hospitalized. The incident occurred on 15th floor at the gas control station.
On August 18, 2025, an employee was lifting a box weighing approximately 30 pounds to prepare it for shipping. He turned to place the box on a bench behind him and felt a pop in his back that caused immediate pain. The employee was hospitalized for herniated discs and required surgery.
An employee was removing a trailer hitch and caught their left middle finger between the tongue of the trailer and the trailer jack, resulting in an amputation to the finger.
Three employees were changing out a belt on a residual cooling fan when the injured employee's middle finger got caught between the belt and pulley. The employee sustained a fingertip amputation.
An employee was diagnosing an alarm on a compressor skid. They were changing out a liquid level switch on the natural gas compressor system when there was a flash fire/explosion. The employee sustained burns to their face and ear, and severe burns to both hands. The employee was hospitalized.
On September 25, 2023, an employee was working in the body department installing doors, hoods, and tailgates. The employee finished their shift and was hospitalized later that evening for a back injury.
An employee was operating an aerial work platform. While the employee was maneuvering the lift through a set of double doors, their head was caught between the door frame and the platform's vertical mast. The employee suffered a skull fracture that required surgery.
An employee was transporting used filter media (containing pyrophoric iron sulfide) from an inlet gas separator in the bed of a truck. The material ignited. While the employee was removing items from the truck bed, a gas can was exposed to the fire and off-gassing vapors ignited. The employee suffered first- and second-degree burns to both arms, the chest, the neck, and the right ear. The employee was hospitalized.
An employee was using a pipe threading machine to thread a 2-inch diameter gas pipe during the rebuilding of a gas meter. The pipe was in a vise mounted on the back of the crew truck. A few pieces of metal chips or shavings caused the threading machine to jam. The employee started to back the pipe up, but it jammed in that direction as well. While reaching to pull the handle back up into place to try and start again, the machine rotated about an inch and pinched his middle fingertip against the edge of the truck s back step. The employee's fingertip was partially amputated without loss of bone.
The injured employee was manually lowering a ramp on a heavy equipment trailer with the assistance of another employee. The injured employee was standing behind the trailer ramp. After removing the safety pins, the ramp descended quickly and struck the injured employee, causing them to fall to the ground. The employee was hospitalized with fractures to their sternum and L1 vertebra.
After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.
An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.
An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.