Direct exposure to electricity, unspecified · Electrical burns, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Buzzi Unicem USA, 1702 Second Ave North, NASHVILLE, TENNESSEE 37208
on — Electrical burns, unspecified, affecting the multiple body parts, n.e.c..
Final narrative
An employee was unhooking power cables from a barge when the metal handle of a cable came in contact with the plug, causing an arc flash. The employee was burned on the arm and torso.
HospitalizedMultiple body parts, n.e.c.Electric parts, n.e.c.
An employee was installing a 15-amp breaker in an electrical panel when a 12-gauge ground wire touched the positive busbar of the panel, resulting in an arc flash. The employee sustained a second-degree burn to their left hand.
An employee was repairing an HVAC system in the drop tile ceiling of a conference room when they were shocked, causing them to fall from the ladder. The employee sustained burns to their right middle and ring fingers.
An employee was replacing a contactor inside an electrical panel attached directly to a press. The press itself was receiving power from another main panel. After replacing the contactor, the employee flipped the switch and an arc flash occurred, burning the employee's elbow, bicep, and neck.
An employee was attempting to switch a medium-voltage primary cable and install a 200-amp fuse barrel. The employee contacted the bottom of the switch gear cradle for the fuse barrel, causing an arc blast. The electricity entered the employee s left hand and exited his big toes, resulting in electric shock and burns to the left hand, arm, shoulder, and both feet. The employee was hospitalized.
On December 6, 2023, an employee of Duke Energy was working on a single-phase 120-/240-volt parallel service re-tap when a secondary flash occurred in an underground service. The employee suffered a second-degree burn to the face and was hospitalized.
More severe injuries in this industry (NAICS 327320)
An employee was walking through the garage and stepped on a mechanic's creeper. His feet went out from under him and he fell, sustaining a fractured right femur.
An employee was exiting a loader and coming down the ladder. His hand slipped off the railing and he fell backward onto sandy ground, landing on his side. The employee was hospitalized with a fractured pelvis and a rotator cuff tear.
A concrete mixer truck driver was walking up the stairs of the slump rack. They fell from the slump rack platform and landed on the ground in the wash-out area. The employee sustained fractures to their left scapula and lower back vertebrae.
An employee backed their concrete truck into place to begin unloading it into a concrete pump unit. He exited the vehicle, and went to the rear to unload. When he began unloading, the truck rolled backward and pinned him against the pump unit. The employee sustained fractures to their pelvis, both femurs, both tibias and fibulas, and their left ankle.
A mechanic was changing out an air spring on a concrete mixer truck cab. The air spring was receiving higher air pressure than it was designed to use, because of a faulty level check valve. This increased pressure caused the air spring to burst. Its top portion separated and struck the employee's left forearm, causing a laceration and fracture. The employee was hospitalized, requiring surgery.
An employee was working to remove a stuck strap from a tray line while on an A-frame ladder. They fell 6 to 8 feet to the concrete floor, resulting in a head contusion and fractured ribs that required hospitalization.
An employee sat on an unleveled bench outside the cafeteria and fell to the concrete. The employee was hospitalized with a head contusion with bleeding and injuries to the right side of her body, her right hip, and right hand, as well as a scrape to her elbow.
An employee was cutting brush and shrubs. A bee stung the employee on the base of their neck. The employee sustained an allergic reaction and was hospitalized.
An employee was walking to his car when he tripped over a board that was secured to the floor of the dock area. His left knee struck the cement dock. The employee was hospitalized and required surgery to repair a broken knee.