Fall through surface or existing opening 16 to 20 feet · Traumatic injuries and disorders, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at A-1 Duran Roofing, Inc., 8095 NW 64 St., MIAMI, FLORIDA 33166
on — Traumatic injuries and disorders, unspecified, affecting the nonclassifiable.
Final narrative
An employee fell approximately 20 feet through the roof to the ground while performing roofing work.
HospitalizedNonclassifiableRoof surfaces other than roof edge
On November 16, 2023, at around 3:30 p.m., a subcontracted employee was painting a door jam on a three-story house when he fell 20 feet through an opened elevator shaft to the floor below. The employee sustained fractured vertebrae that required hospitalization.
Employees were removing and replacing skylights on a metal roof. The injured employee's lanyard became tangled and they fell through the skylight to the ground 16-18 feet below. The employee suffered fractures to the wrist, ribs, and hip.
An employee was requested by a client to string wire on top of an auditorium. He used a boom lift to access a beam and then exited the boom lift to walk on the beam. He then stepped down on a drop ceiling, lost balance, and fell. The drop ceiling caved in and the employee fell 20 feet onto bleachers sustaining injury to his abdominal area and lower left leg. The employee was wearing a harness, but it was not connected to an anchoring point at the time of the fall.
An employee was installing decking (steel grates) in a new construction steel framed building. The employees were working approximately 22' above the next lower level, which was a concrete ground floor. The decking was pre-cut with the floor opening prior to installation. Shortly after installing the floor opening, the employee fell through the floor opening, approximately 18' onto a section of metal ductwork, resulting in fractures to the skull, ribs, thorax, and lumbar vertebra, as well as an ear laceration.
An employee was taking measurements of an area for drywall when they stepped backward into a partially covered hole in the floor. The employee fell approximately 17 feet to the level below, sustaining a forehead fracture and avulsion, a right shoulder dislocation, a left forearm fracture, left knee tendon and meniscus tears, as well as multiple contusions and abrasions.
More severe injuries in this industry (NAICS 238160)
An employee was delivering materials. He was doing his pre-delivery inspection on the roof of the jobsite (a warehouse) when he fell through a plexiglass skylight. He landed on his feet on the concrete floor 14 feet below. The employee sustained fractures to his spine, left ulnar/radius, and right heel. The employee required surgery.
An employee was standing on a multi-purpose ladder installing head flashing over a window. Their feet were approximately 6 feet off the ground and three rungs from the top. The employee lost their grip on the drill they were using and the ladder tipped over. The employee fell from the ladder to the ground, resulting in a fractured left wrist, bruised chest, and lacerations to their face and lip.
An employee fell through a hole in the ceiling and suffered injuries to his side and right arm. When he fell, a piece of concrete fell with him and struck his arm. He was hospitalized.
An employee was laying glue on the corner of a three-story commercial flat roof to apply new thermoplastic polyolefin roofing material. He lost his balance and fell at least 35 feet to the concrete ground below. The employee sustained fractures.
An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.
An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.
An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.
An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.