105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

MAsTec Services Company, Inc.

Indirect exposure to electricity, unspecified · Electrocutions, electric shocks

Federal OSHA recorded a severe workplace injury at MAsTec Services Company, Inc., 2210 vandebilt Beach, NAPLES, FLORIDA 34109 on — Electrocutions, electric shocks, affecting the bODY SYSTEMS.

An employee was working to replace a lightning arrester( electrical distribution work). When the tool he was using came in proximity to an energized jumper coming from the top of the lightning arrester, an arc flash occurred.

Hospitalized BODY SYSTEMS Nonclassifiable

MasTec Services Company, Inc.

An employee was walking on uneven, rocky ground alongside a shallow trench less than 3 feet deep while installing electric utility conductors. The employee fell into the trench and landed on his left foot, resulting in a hairline fracture of the lower left leg that required hospitalization and surgery.

MasTec Services Company, Inc.

An employee was on the ground working on a de-energized-by-design pole guy wire. The guy wire became energized by an overhead electric source. The employee sustained electric burns to their left hand and right knee and was hospitalized for treatment.

MasTec Services Company, Inc.

An employee was helping a machine operator load a personnel bucket onto a trailer when the employee was struck by the boom of a rear-easement backyard digger-derrick machine. The employee suffered fractures to the ribs, hips, and right femur.

MasTec Services Company, Inc.

An employee was cleaning an underground electrical vault. The employee was shocked, fell from the stepladder, and was injured. The employee's left hand was amputated due to the electric shock.

MasTec Services Company, Inc.

An employee was attempting to remove a drive gear from beneath equipment. The employee was operating a pneumatic drill with his left hand while bracing himself with his right hand on the drive gear. The torque of the drill caused the gear to shift and catch the distal phalange of his right pinky finger, resulting in a partial amputation.

View MAsTec Services Company, Inc.'s full OSHA safety record →

AAXIOM CONCRETE SAWING, LLC

An employee was coring a concrete slab when their drill contacted a live electrical conduit. The employee suffered an electrical shock.

D-T Steel Inc

An employee was welding clips onto the end of the bridging of a wall, then installing bolts through the clips to the wall. As the employee lowered his rod holder down into the lift basket, the rod contacted the basket and energized it. As the employee leaned forward, they contacted the basket and grounded joist, resulting in first- and second-degree electrical burns to the stomach, back, and arms.

High Country Line Construction Inc

An employee was on the ground preparing to receive a wire stringing steel rope being flown by a helicopter. The employee grabbed the steel line and was shocked by electricity from the line on his right hand. The employee was hospitalized and required surgery for nerve damage to his hand.

Ernest P. Breaux Electrical, Inc.

An employee was pulling a line through a light pole when it contacted an uninsulated line. The employee was shocked and sustained burns that required hospitalization.

West Penn Power

An employee was in a bucket truck drilling a hole into a utility pole when a conductor located above the employee broke free from the pole and fell onto the equipment. The employee suffered second-degree burns to the right side of their face.

Smart Building Technologies - A Fidelity Company

An employee was troubleshooting the control setup for a variable air volume box above a ceiling. The employee's hand came into contact with an exposed, energized 277-volt wire that had loosened from its terminal on the box's assembly. He was shocked and fell off a ladder. His left hand passed across the ceiling grid and was lacerated. He also suffered an electrical burn to the right hand and was hospitalized.

Abbott Electric Inc

An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.

Mintcrest Corp

An employee was standing on an A-frame ladder approximately 6 feet above the floor while he attached a suspended light fixture to the ceiling. The employee lost balance, and fell to the tiled floor below, sustaining blunt force trauma to his head.

Cupertino Electric, Inc.

An employee was inspecting the overhead area of a single-person lift and repositioning the lift through a double doorway. As they were transitioning through the doorway, they were caught between the doorframe and the vertical mast of the lift. The employee was hospitalized with injuries to the nose, left maxillary sinus, left orbital bone, and left jaw, with fractures at the maxillary sinus area.

Swedberg Electric, LLC

The injured employee was performing routine maintenance on a fan belt/pulley. The injured employee and another person were moving the pulley back and forth manually to find a bearing issue. The injured employee's left ring finger got caught between the belt and the pulley wheel, resulting in a soft tissue amputation.

DRIFTWOOD NURSERY & LANDSCAPING, INC

An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.

Hobby Lobby Stores, Inc.

An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

Sugar Cane Growers Cooperative of Florida

An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.

Air-flo/Erwood Heating & Air Conditioning

An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.