Federal OSHA recorded a severe workplace injury
at Instrument Transformers, LLC, 1907 Calumet St, CLEARWATER, FLORIDA 33765
on — Amputations, affecting the finger(s), fingernail(s), unspecified.
Final narrative
An employee was operating the winding machine and knelt down to get a better view. His knee gave out and he fell forward extending his hand to brace himself. His hand contacted the machine blade and amputated the right middle finger.
An employee was adjusting a mechanical press and using a prybar on the shaft to reset the cutter and crankshaft to the home position. The employee went to move the shaft, but it caught the flywheel with the momentum. This caused the shaft and prybar to spin around. The prybar struck his left middle fingertip and amputated it.
While diagnosing a vacuum system, an employee removed an exhaust filter to access a vacuum port with his right thumb. The ball valve actuated while his thumb was in the port, amputating his thumb tip.
An employee was pulling on a bale of corrugated cardboard boxes that were on a conveyor. The straps on the bale failed and the employee fell to the floor. The employee was hospitalized and required surgery for a fractured femur and/or hip.
On December 27, 2023, an employee was delivering mail to an apartment complex when their knee gave out and they fell to the ground. The employee was hospitalized with a left tibia fracture.
An employee was walking to the inventory cage when her ankle gave out and she fell to the floor. The employee sustained a femur fracture and was hospitalized.
An employee was dislodging a pallet that was stuck when boxes of product fell onto them, causing them to fall to the ground. The employee suffered a fractured femur.
An employee was checking a pole-type transformer tank for leaks. A hydraulic clamping device was lowered onto his right thumb and crushed it against the sharp edge of the bottom of the tank. He suffered a partial transphalangeal amputation to the thumb.
An employee was troubleshooting a machine. He was investigating a slipping belt when it caught his left hand and pulled it into a pulley, partially amputating the tip of his thumb.
An employee was tilting a radiator in a fixture. The radiator moved in the fixture and crushed the employee's left index fingertip, causing an amputation.
An employee installed a busbar on a coil for a winding machine. The busbar hit a tension bar, causing his left ring finger to get caught between the coil and the tension bar, which pulled in the employee's glove and resulted in a medical fingertip amputation. The machine was guarded at the time.
An employee was operating a wire winding machine when their clothing was caught in a rotating component, pulling them into the equipment. The employee's right arm was fractured.
An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.
An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.
An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.