Caught in running equipment or machinery during regular operation · Multiple nonspecified injuries and disorders
At a glance
Federal OSHA recorded a severe workplace injury
at Nike IHM, Inc., 8 Research Park Drive, SAINT CHARLES, MISSOURI 63304
on — Multiple nonspecified injuries and disorders, affecting the hand(s), unspecified.
Final narrative
While attempting to feel the line in an extrusion line winder reel, an employee's hand was pulled into the machine, causing hand bruising and swelling.
An employee was applying a bevel to a 5" brass component with a 12" disc sander. The disc sander came off and struck him, resulting in an amputation to his right thumb.
An employee was sharpening peeler blades when their shirt was caught in the grinding wheel. The employee sustained tendon damage and a crushed right hand.
An employee was preparing to cut lumber on a panel saw when the clamp engaged and caught the employee's left middle finger, resulting in a fingertip amputation.
More severe injuries in this industry (NAICS 325211)
An employee was monitoring a rotary press when his left hand became caught in the machinery. The employee's left middle finger was amputated at the distal interphalangeal joint.
An employee was sweeping in an area with powdered PVC on the floor and began having difficulty breathing and coughing up blood, The employee was hospitalized for inhalation of PVC.
An employee was working on a pastillator machine, which processes resin-based materials into solid pastilles. His right hand became caught between the feed roller (operating at approximately 350 F) and the cooling belt. The employee s glove and shirt sleeve adhered to his arm due to the heat. The employee sustained third-degree burns to his right hand and forearm, requiring hospitalization and surgery.
An employee was troubleshooting a leak on a low pressure (less than 50 PSI) condensate line in the oxidation area of the plant. He was working to remove insulation around a valve when either the valve or the line failed, and hot condensate contacted his right arm, right abdomen area, and the front of both legs, resulting in second- and third-degree burns.
An employee was replacing a fan on a cooling unit. As he went to adjust a pump, the unit caught his right hand and the fan blades severely lacerated his index finger. He underwent a medical amputation to the finger.
An employee was readjusting a safety hook to remove hardware from gang forms when his feet slipped. He fell to the ground, resulting in a broken left arm and wrist.
An employee was on a step ladder in a store aisle, making room on shelving for merchandise. She fell from the step ladder to the floor, suffering two fractures in her left leg. She was hospitalized, requiring surgery.
An employee was closing the side cargo door to a company van. The tip of his finger got caught between the door and the door jamb, resulting in a partial amputation.