105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Formosa Plastics Corporation, U.S.A.

Fall on same level, n.e.c. · Soreness, pain, hurt-nonspecified injury

Federal OSHA recorded a severe workplace injury at Formosa Plastics Corporation, U.S.A., 9 Peach Tree Hill Rd., LIVINGSTON, NEW JERSEY 07039 on — Soreness, pain, hurt-nonspecified injury, affecting the knee(s).

An employee was pushing a chair with wheels into a conference room. The employee's knee "popped" and she fell. The employee suffered a knee injury that required surgery.

Hospitalized Knee(s) Floor, n.e.c.

Abbott-Action, Inc.

An employee was pulling on a bale of corrugated cardboard boxes that were on a conveyor. The straps on the bale failed and the employee fell to the floor. The employee was hospitalized and required surgery for a fractured femur and/or hip.

United States Postal Service

On December 27, 2023, an employee was delivering mail to an apartment complex when their knee gave out and they fell to the ground. The employee was hospitalized with a left tibia fracture.

Millennium Mat Company

An employee was walking to the inventory cage when her ankle gave out and she fell to the floor. The employee sustained a femur fracture and was hospitalized.

Publix Super Markets, Inc.

An employee was dislodging a pallet that was stuck when boxes of product fell onto them, causing them to fall to the ground. The employee suffered a fractured femur.

General Polymeric Corporation

An employee was monitoring a rotary press when his left hand became caught in the machinery. The employee's left middle finger was amputated at the distal interphalangeal joint.

MCM Plastics, Inc.

An employee was sweeping in an area with powdered PVC on the floor and began having difficulty breathing and coughing up blood, The employee was hospitalized for inhalation of PVC.

Lawter Inc.

An employee was working on a pastillator machine, which processes resin-based materials into solid pastilles. His right hand became caught between the feed roller (operating at approximately 350 F) and the cooling belt. The employee s glove and shirt sleeve adhered to his arm due to the heat. The employee sustained third-degree burns to his right hand and forearm, requiring hospitalization and surgery.

AdvanSix, Inc.

An employee was troubleshooting a leak on a low pressure (less than 50 PSI) condensate line in the oxidation area of the plant. He was working to remove insulation around a valve when either the valve or the line failed, and hot condensate contacted his right arm, right abdomen area, and the front of both legs, resulting in second- and third-degree burns.

Rochling Machined Plastics

An employee was replacing a fan on a cooling unit. As he went to adjust a pump, the unit caught his right hand and the fan blades severely lacerated his index finger. He underwent a medical amputation to the finger.

JERSEY CITY MEDICAL CENTER

An employee tripped over a stool and fell on the floor, resulting in a left displaced mid-cervical femoral neck fracture.

APM TERMINALS PORT ELIZABETH

An employee was installing fence posts when they stepped into a recently dug hole that was not visible due to rainfall. The employee's leg was fractured.

Allied Waste Systems Inc

An employee assisted in cleaning material from a conveyor pit. After the pit was cleaned, the employee proceeded to replace metal safety plates to ensure other employees did not fall into the pit. While replacing one of the last plates, the employee mis-stepped and fell approximately 5 feet into the pit. The employee was hospitalized with back/side bruising, elbow bruising, bone bruises, and/or fractured ribs.

Fitness International, LLC

An employee was inspecting a breaker box and turning on/off a circuit breaker when he was electrocuted.

Bristol Myers Squibb