Caught in running equipment or machinery during maintenance, cleaning · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at Zacros America, Inc. (Hedwin Division), 220 Lake Drive, NEWARK, DELAWARE 19702
on — Amputations, affecting the fingertip(s).
Final narrative
An employee was attempting to free bridged material in a regrind feeder when an auger struck and amputated his right pointer, middle, and ring fingertips.
HospitalizedAmputationFingertip(s)Metal, woodworking, and special material machinery, n.e.c.
Two employees were repairing the hydraulic engagement pins on a rented front-end wheel loader. The machine controls were activated to move the attachment pins and an employee's finger was caught between the pins and the bushings. Their right index finger was partially amputated.
An employee was cleaning the conveyor on a piece of equipment when they slipped and their right hand was pulled into the chain sprocket. The employee's fifth fingertip was amputated.
An employee was throwing blankets onto a blanket folding and stacking machine. A blanket got stuck in the machine and she attempted to remove it when the machine contacted her right little finger, resulting in a fingertip amputation.
More severe injuries in this industry (NAICS 326199)
An employee was operating a drill and tap machine. He was placing a part with his right hand and removing a part coming in on the left side. He saw a part that was crooked and went to straighten it. The machine clamped down on his left index finger, degloving the top part of the finger and resulting in a partial amputation.
An employee was performing maintenance on a roll cutting machine in a warehouse. The employee was removing excess grease from the bearings when the machine's chain caught their right index finger. The fingertip was amputated by the chain and sprocket.
During fiberglass work, an employee mixed a methyl ethyl ketone peroxide (MEKP) catalyst with a cobalt chemical that they thought was a dye. A chemical reaction occurred, resulting in an explosion. The employee sustained second-degree burns on his back and a blister on his right arm.
An employee was walking when she tripped over a box on the ground and fell. The employee was hospitalized with a severe dislocation to the hip and leg that required surgery.
A flagger was directing traffic flow in a highway work zone. They were standing approximately 1.5 feet behind the shoulder's demarcating line, next to and slightly behind a traffic drum. As they were directing traffic into and out of the driveway of a parking lot, a car attempted to get around a truck and struck the traffic drum, which subsequently struck the employee, who was thrown 15 feet and landed on top of concrete aggregate. The employee suffered pelvic and rib fractures, T10 and L3 vertebra fractures, and internal bleeding.
An employee was troubleshooting a power washer in the field. Because there might have been water in its fuel, he brought it back to the shop and drained about a gallon of fuel from the tank into a plastic container. Some of the fuel spilled onto the floor and ignited. The employee was stomping out the fire when he lost his balance and tripped into a stool, which caused the plastic container to spill more fuel onto the fire. The employee's pants and shirt caught on fire, and he fell, abrading his knee while trying to get through the flames. As well as the knee abrasion, he suffered burns to the left leg and left lower quadrant of the torso. He was hospitalized.
An employee was backing up a tram (towing powered industrial equipment) to connect it to a trash bin. The employee's left forearm/wrist was caught and crushed between the tram and the bin. The employee was hospitalized.
An employee went to lift a carton and tripped on a different carton that was on the floor. She fell on the floor in the backroom and sustained a fractured right hip, and abrasions to her arm and knee. The employee was hospitalized and required surgery.