Struck by falling object or equipment, unspecified · Internal injuries to organs and blood vessels of the trunk
At a glance
Federal OSHA recorded a severe workplace injury
at North Houston Pole Line, L.P., 15482 Miller Road 1, HOUSTON, TEXAS 77049
on — Internal injuries to organs and blood vessels of the trunk, affecting the chest, except internal location of diseases or disorders.
Watch North Houston Pole Line, L.P. — freeGet an email when a new federal OSHA severe-injury report for North Houston Pole Line, L.P. is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was removing a wood utility pole from a hole when the pole slipped. The employee was then caught between the pole and an adjacent truck, suffering a collapsed lung and breaking ribs, an ulna, and a radius. The employee was hospitalized.
HospitalizedChest, except internal location of diseases or disordersUtility and telephone poles
More severe injuries at North Houston Pole Line, L.P.
An employee was helping to remove a control cable from a cell tower. The end of a wire came close to an adjacent power line, a 138-kilovolt transmission line, resulting in an arc flash. The employee sustained burns to their hands and arms.
An employee was disassembling a temporary transmission structure. A conductor butterfly shoe broke as the employee removed it, which caused a polymer stand-off insulator to release and strike the employee in the face. The employee sustained a fractured jaw.
An employee was climbing down from a crane after loading it onto a lowboy trailer. He fell to the ground about 4 feet below and suffered a spiral fracture to the lower right leg.
An employee was unloading 30-foot 2-inch barrels from a pan holding about 20 barrels. The barrels tipped over, striking and breaking both of the employee's lower legs.
An employee was in a sandblasting area, preparing the surface of a plate heat exchanger frame for painting. The frame fell on the employee, who suffered fractures to vertebrae, the neck, pelvis, and rib cage; and punctured lungs.
An employee was terminating cables in a junction box. A loose ground wire came into contact with the bushing, causing a flash that burned the right side of the employee's face and his right hand.
An employee was using a bucket truck hoist to raise secondary aerial wiring. The wire made contact with the primary wire, causing an arc flash. The employee suffered burns to both hands and was hospitalized.
An employee was terminating conductors to buss bars inside the secondary compartment of a single-phase transformer. An arc flash occurred, causing burns to the soft tissue of the employee's face.
An employee was securing the claw of a grapple truck to the truck bed. His left little finger was caught between the tie down strap and the rub rail of the truck, resulting in partial amputation of the finger.
After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.
An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.
An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.