Compressed or pinched by shifting objects or equipment · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Wagner Equipment Co, 15415 CO-14, AULT, COLORADO 80610
on — Fractures, affecting the leg(s), unspecified.
Final narrative
An employee was climbing into a service truck while a coworker was moving an excavator into the parking area. The excavator boom struck the service truck door, which closed on the employee and broke his left leg.
An employee was installing a regulator onto a compressed oxygen tank to prepare to use an oxygen/acetylene torch when a fire erupted. The employee sustained burns to their right forearm, chin, and neck.
An employee was operating a forklift and unloading a truck. After the truck was unloaded, the employee got off the forklift and proceeded to adjust the dock plate with a hook tool. The dock plate slipped and the employee went to adjust the plate with their hand when their left middle finger got caught. Their finger was amputated above the first joint.
An employee was rotating a carbide granulator blade when his finger was caught between the blade and a stationary part of the machine. The employee's right middle finger was partially amputated and they suffered an avulsion to the right ring fingertip.
An employee was using a CNC metal lathe machine in manual mode to check that the thread blocking tool made contact with the jaws. As the employee was manually spinning the spindle, his index fingertip was crushed between the spindle's jaws and the grooving insert, resulting in a fingertip amputation.
During a material handling operation, an employee's fingertip was caught under an air conditioning unit as the unit was lowered onto a cart. The employee's fingertip was amputated.
An employee was removing a bolt from a tractor hub when their right index finger was caught between the hub and the frame. The employee's fingertip was crushed and the employee was hospitalized.
More severe injuries in this industry (NAICS 532412)
An excavator bucket was being removed. An employee was pulling a snap ring to remove a pin and lost his grip. The high-tension snap ring recoiled and his left middle fingertip was amputated by the snap ring.
An employee was walking between service bays. He came into contact with a trailer hitch, which was sticking out of the back of a lawn mower, and fell to the concrete floor. He landed on his right side and suffered a broken hip.
An employee was taking a scissor lift off a flatbed trailer. While using the remote operator controls and walking alongside the lift, the wheel of the lift turned in the wrong direction, causing it to strike the employee and roll over his left ankle. The employee was hospitalized with two broken bones in his ankle.
An employee was working on an excavator's tracks. He was swinging a sledgehammer to finish pushing a metal tractor pin into the track links. A hammer-blow caused a piece of the pin to fly off, ricochet, and embed itself in his buttock. He was hospitalized, requiring surgery.
An employee was picking up crane pads to put onto their trailer. Their finger got pinched between pads, resulting in an amputation involving the loss of skin.
An employee was delivering materials. He was doing his pre-delivery inspection on the roof of the jobsite (a warehouse) when he fell through a plexiglass skylight. He landed on his feet on the concrete floor 14 feet below. The employee sustained fractures to his spine, left ulnar/radius, and right heel. The employee required surgery.
An employee was removing packaging from a roll of printing substrate. The blade of their utility knife got stuck. The employee used both hands to free the knife and the blade partially amputated their left little fingertip.
A concrete batch plant operator was assisting with clearing spoil piles using a skid steer. The skid steer backed into a stationary screen plant. The employee's left little finger was crushed between the controls of the skid steer and the screen plant, resulting in a fracture and laceration. The employee's finger was surgically amputated.
An employee was standing on an extension ladder, using a torquing tool to remove bolts that secured blades to a rotor. When the torquing tool activated, its reaction arm came around and pinched the employee's right middle finger against a lifting eye. His fingertip was amputated.