Caught in running equipment or machinery, n.e.c. · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at Ticona Polymers, Inc., 5738 County Rd 4, BISHOP, TEXAS 78343
on — Amputations, affecting the finger(s), fingernail(s), n.e.c..
Watch Ticona Polymers, Inc. — freeGet an email when a new federal OSHA severe-injury report for Ticona Polymers, Inc. is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee amputated his right middle finger while working in the compounding unit as he was prepping to clean a product tank.
An employee was performing a gaging around, checking outside operating conditions, and inspecting the equipment in the pharmaceutical unit. A pressurized hose connected to a process line and containing a contaminated chemical mixture of nitrogen and hydrochloric acid was nearby. The hose was pressurized but not flowing; it was closed by the valve. The employee was 3 to 5 feet from the hose when it became disconnected. He sustained burns to his abdomen, arm, and face.
Employees were assembling and testing a butterfly valve unit and actuator combo. When the unit was function tested with air, the valve gate closed on an employee's left thumb resulting in a fracture and laceration.
An employee was doing a daily inspection of the sifter screen on a mixer when the mixer line activated. The armature for the screen struck the employee's right wrist. Their wrist was cut and their hand was fractured.
An employee was doing a dry run during the setup of an ice cream machine. The machine indexed and the filler head amputated the employee's left middle finger above the last knuckle.
An employee was on a 3-foot ladder guiding cable onto a spool during installation on an overhead door. As the control box was jogged, the employee's hand was caught between the cable and spool, resulting in a wrist and hand fracture.
More severe injuries in this industry (NAICS 325211)
An employee was monitoring a rotary press when his left hand became caught in the machinery. The employee's left middle finger was amputated at the distal interphalangeal joint.
An employee was sweeping in an area with powdered PVC on the floor and began having difficulty breathing and coughing up blood, The employee was hospitalized for inhalation of PVC.
An employee was working on a pastillator machine, which processes resin-based materials into solid pastilles. His right hand became caught between the feed roller (operating at approximately 350 F) and the cooling belt. The employee s glove and shirt sleeve adhered to his arm due to the heat. The employee sustained third-degree burns to his right hand and forearm, requiring hospitalization and surgery.
An employee was troubleshooting a leak on a low pressure (less than 50 PSI) condensate line in the oxidation area of the plant. He was working to remove insulation around a valve when either the valve or the line failed, and hot condensate contacted his right arm, right abdomen area, and the front of both legs, resulting in second- and third-degree burns.
An employee was replacing a fan on a cooling unit. As he went to adjust a pump, the unit caught his right hand and the fan blades severely lacerated his index finger. He underwent a medical amputation to the finger.
After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.
An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.
An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.