Caught in running equipment or machinery during maintenance, cleaning · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at JOHNSON CONTROLS, 4722 PEAR STREET, SAINT JOSEPH, MISSOURI 64501
on — Amputations, affecting the finger(s), fingernail(s), n.e.c..
Final narrative
An employee was attempting to clear a jam of material from a trim conveyor on the back side of a strip caster when his finger was caught in the chain drive sprocket. His left ring finger was amputated just below the first knuckle. The chain was unguarded and the conveyor was not locked out at the time of the incident.
On July 23, 2025, an employee was conducting HVAC work in a mechanical room that had an ambient temperature of 110- to 120-degrees. At the end of the day, he experienced dizziness, cramping, and became ill. The employee was hospitalized for heat stress and dehydration.
An employee was accessing the motor of a rooftop HVAC unit when a gust of wind caused the HVAC access door to close on their left hand. The employee sustained an amputation of their ring finger through the phalanx.
An employee was rolling a screen for a dry chemical manufacturing grinder down a flight of stairs. The rolling screen went out of control and he fell, coming to rest 18 steps below and suffering a broken left femur.
Two employees were repairing the hydraulic engagement pins on a rented front-end wheel loader. The machine controls were activated to move the attachment pins and an employee's finger was caught between the pins and the bushings. Their right index finger was partially amputated.
An employee was cleaning the conveyor on a piece of equipment when they slipped and their right hand was pulled into the chain sprocket. The employee's fifth fingertip was amputated.
An employee was throwing blankets onto a blanket folding and stacking machine. A blanket got stuck in the machine and she attempted to remove it when the machine contacted her right little finger, resulting in a fingertip amputation.
More severe injuries in this industry (NAICS 335912)
An employee was demonstrating how to disassemble and reassemble a metal filter unit from the cathode powder transfer line. During the open/close operation of an automated valve, the employee s latex glove became caught. The employee sustained a partial amputation to the left index finger.
On March 5, 2025, an employee was pushing an 8-foot x 12-foot x 2-foot electrical panel weighing 3 tons into the electrode room when the panel tipped over, striking his leg. The employee sustained a fractured right femur.
An employee was readjusting a safety hook to remove hardware from gang forms when his feet slipped. He fell to the ground, resulting in a broken left arm and wrist.
An employee was on a step ladder in a store aisle, making room on shelving for merchandise. She fell from the step ladder to the floor, suffering two fractures in her left leg. She was hospitalized, requiring surgery.
An employee was closing the side cargo door to a company van. The tip of his finger got caught between the door and the door jamb, resulting in a partial amputation.
An employee lost his footing while climbing an inclined ladder. He stumbled down one step and was able to stabilize himself by holding the railing and twisting his body, but he suffered an internal abdominal injury and was hospitalized.