Shermco Industries Inc.

Direct exposure to electricity, unspecified · Electrical burns, unspecified

Federal OSHA recorded a severe workplace injury at Shermco Industries Inc., 12100 Samsung Blvd, Cub 2 Bldg, AUSTIN, TEXAS 78754 on — Electrical burns, unspecified, affecting the arm(s), unspecified.

Watch Shermco Industries Inc. — free Get an email when a new federal OSHA severe-injury report for Shermco Industries Inc. is published. One employer, no account, unsubscribe in one click.

An employee was testing electrical cables. An arc flash occurred while the employee was putting rubber boots back on resulting in an electrical burn to the left arm.

Hospitalized Arm(s), unspecified Electric parts, unspecified

Shermco Industries, Inc.

The injured employee and employee 2 were lifting a filter housing (air bonnet) in preparation for a motor lift and removal at a client site. The filter housing shifted and the injured employee s left middle finger was caught between the filter housing and the concrete floor. The finger was partially amputated.

Shermco Industries, Inc.

An employee had set down an electrical breaker box inside a motor control center he was preparing to replace the breaker in. He turned to walk away and an electrical arc flashed out of the open door of the cabinet, burning his palms and wrist and causing a slight burn to his right cheek.

View Shermco Industries Inc.'s full OSHA safety record →

Bob Woodall Air Care Systems, Inc.

An employee was installing a 15-amp breaker in an electrical panel when a 12-gauge ground wire touched the positive busbar of the panel, resulting in an arc flash. The employee sustained a second-degree burn to their left hand.

Amentum Spaceport LLC

An employee was repairing an HVAC system in the drop tile ceiling of a conference room when they were shocked, causing them to fall from the ladder. The employee sustained burns to their right middle and ring fingers.

Marsh Bellofram Corporation

An employee was replacing a contactor inside an electrical panel attached directly to a press. The press itself was receiving power from another main panel. After replacing the contactor, the employee flipped the switch and an arc flash occurred, burning the employee's elbow, bicep, and neck.

Heart Utilities of Jacksonville, Inc.

An employee was attempting to switch a medium-voltage primary cable and install a 200-amp fuse barrel. The employee contacted the bottom of the switch gear cradle for the fuse barrel, causing an arc blast. The electricity entered the employee s left hand and exited his big toes, resulting in electric shock and burns to the left hand, arm, shoulder, and both feet. The employee was hospitalized.

Duke Energy Florida, LLC

On December 6, 2023, an employee of Duke Energy was working on a single-phase 120-/240-volt parallel service re-tap when a secondary flash occurred in an underground service. The employee suffered a second-degree burn to the face and was hospitalized.

Fluor

An employee was working to free a load by grabbing and shaking the live side of a tugger line. Once the load became free and progressed upward, the employee's hand was caught and pulled into a snatch block. The employee's right thumb was broken and lacerated. The employee was hospitalized and required a surgical amputation.

UES Professinoal Solutions, LLC

An employee was operating a drill rig when when their hand got caught between a 1/4-inch steel cable and a drill rod, resulting in the amputation of four fingers.

Elecnor Hawkeye, LLC

An employee was overseeing the operation of a rope being respooled onto the drum of a wire winding machine. He went to remove a piece of wooden reel from the rope. His glove got snagged and his right hand was pulled into the roller, pinching his fingers between the machine's roller and the rope. The middle and index fingers were crushed.

WEST AFFUM DEVELOPMENT CO LLC

An employee was visiting a patient's home to fit them with a wearable cardiac defibrillator. As he was walking from the front door to his car, a large dog broke free from a chain and attacked him. He was bitten on the forearm and fell. The patient was then able to restrain the dog. The employee was hospitalized with severe dog bites and required surgery.

Day & Zimmermann

An employee tripped over a junior I-beam about 4 feet long and 6 inches tall that was installed for circulating water valves and fell to the ground, resulting in a broken right-side rib.

T G Meat Center LLC

After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.

Professional Flooring Supply

An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.

EnviroSafe Demil LLC

An employee was inspecting flares processes. The employee received burns to the front side of the body, face and arm from the flares.

Inteplast Group

An employee was removing plastic material from a production line when the machine cycled and amputated his left index, ring, and little fingers.

Regency IHS of Fairwinds Halletsville, LLC

An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.