105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Florida Power and Light

Compressed or pinched by shifting objects or equipment · Amputations

Federal OSHA recorded a severe workplace injury at Florida Power and Light, Pratt and Whitney Across, JUPITER, FLORIDA 33478 on — Amputations, affecting the finger(s), fingernail(s), unspecified.

Watch Florida Power and Light — free Get an email when a new federal OSHA severe-injury report for Florida Power and Light is published. One employer, no account, unsubscribe in one click.

An employee was moving a crane and outriggers when his middle finger was pinched between the lip of an outrigger and the crane, resulting in a partial amputation.

Hospitalized Finger(s), fingernail(s), unspecified Cranes, unspecified

Florida Power and Light

An employee was working on an out-of-service electrical pole. While he was up the pole on a ladder, and then on hooks, his hand touched with a primary voltage jumper that had burnt off at the transformer. He suffered an entry wound through the little finger and out the back of his arm behind the elbow.

FLORIDA POWER AND LIGHT

An employee was in the rear of the property looking for an electric service handhole. The employee stepped onto a plastic stool bench in order to see over the fence. The employee lost his balance and suffered a puncture injury underneath the armpit from climbing spikes protruding from a communications pole.

Florida Power and Light

An employee was moving a transformer on a dolly. The transformer slipped off the dolly and crushed the employee's left middle finger.

Florida Power and Light

An employee was repairing a meter. The meter's glass cover shattered and the employee's left wrist was lacerated.

Florida Power and Light

An employee was attempting to undo a sling between a crew material handler truck that was struck in the mud and a four-wheeled pickup truck that was pulling the crew material handler truck when the four-wheeled truck rolled back, pinning his right leg. He suffered lacerations, punctures, and a damaged main artery behind his right knee, requiring hospitalization.

View Florida Power and Light's full OSHA safety record →

TForce Freight

An employee was operating a forklift and unloading a truck. After the truck was unloaded, the employee got off the forklift and proceeded to adjust the dock plate with a hook tool. The dock plate slipped and the employee went to adjust the plate with their hand when their left middle finger got caught. Their finger was amputated above the first joint.

Liveo Research, Inc.

An employee was rotating a carbide granulator blade when his finger was caught between the blade and a stationary part of the machine. The employee's right middle finger was partially amputated and they suffered an avulsion to the right ring fingertip.

Best Pump and Flow

An employee was using a CNC metal lathe machine in manual mode to check that the thread blocking tool made contact with the jaws. As the employee was manually spinning the spindle, his index fingertip was crushed between the spindle's jaws and the grooving insert, resulting in a fingertip amputation.

FORD MOTOR COMPANY

During a material handling operation, an employee's fingertip was caught under an air conditioning unit as the unit was lowered onto a cart. The employee's fingertip was amputated.

Lasseter Tractor Company. Inc.

An employee was removing a bolt from a tractor hub when their right index finger was caught between the hub and the frame. The employee's fingertip was crushed and the employee was hospitalized.

Alabama Power Company

Employees were pulling three-phase power lines to a power pole. An employee's hand was caught between a pulley and a rope, resulting in amputation of the employee's index, middle, and ring fingertips.

Public Service Company of Colorado

An employee was cutting through two secondary wires with a battery-powered cutting tool. The wires were energized at 120/240 volts; when the employee cut through the insulation around a wire, an arc flash burned the employee's left thumb.

GEORGIA POWER COMPANY

An employee had been preparing material for a lineman at a jobsite and was pulling up wire on a hand line. The employee began to feel ill, suffering from heat illness.

Georgia Power

An employee's right hand was broken after being struck by an excavator that was being moved.

JF ELECTRIC, INC.

An employee was tamping at the base of a power pole when they were struck by an extendable hot arm that was dropped from an aerial bucket. The employee sustained two broken ribs on the right side, and a pneumothorax on the right side.

DRIFTWOOD NURSERY & LANDSCAPING, INC

An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.

Hobby Lobby Stores, Inc.

An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

Sugar Cane Growers Cooperative of Florida

An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.

Air-flo/Erwood Heating & Air Conditioning

An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.