105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

ABM Building Solutions, LLC

Direct exposure to electricity, unspecified · Electrical burns, unspecified

Federal OSHA recorded a severe workplace injury at ABM Building Solutions, LLC, 6606 LBJ Freeway, DALLAS, TEXAS 75240 on — Electrical burns, unspecified, affecting the arm(s), unspecified.

Two employees were shutting down equipment to move a condenser's breaker box from one building to another when an arc flash occurred, burning their left and right arms.

Hospitalized Arm(s), unspecified Nonclassifiable

ABM Building Solutions, LLC.

An employee was working on an HVAC on top of a roof when the employee fell 25 feet through the skylight to the floor below. The employee was hospitalized for broken bones.

ABM Building Solutions, LLC.

An employee was loading an exhaust fan on a flatbed truck when his left shin hit the fan and was lacerated.

View ABM Building Solutions, LLC's full OSHA safety record →

Bob Woodall Air Care Systems, Inc.

An employee was installing a 15-amp breaker in an electrical panel when a 12-gauge ground wire touched the positive busbar of the panel, resulting in an arc flash. The employee sustained a second-degree burn to their left hand.

Amentum Spaceport LLC

An employee was repairing an HVAC system in the drop tile ceiling of a conference room when they were shocked, causing them to fall from the ladder. The employee sustained burns to their right middle and ring fingers.

Marsh Bellofram Corporation

An employee was replacing a contactor inside an electrical panel attached directly to a press. The press itself was receiving power from another main panel. After replacing the contactor, the employee flipped the switch and an arc flash occurred, burning the employee's elbow, bicep, and neck.

Heart Utilities of Jacksonville, Inc.

An employee was attempting to switch a medium-voltage primary cable and install a 200-amp fuse barrel. The employee contacted the bottom of the switch gear cradle for the fuse barrel, causing an arc blast. The electricity entered the employee s left hand and exited his big toes, resulting in electric shock and burns to the left hand, arm, shoulder, and both feet. The employee was hospitalized.

Duke Energy Florida, LLC

On December 6, 2023, an employee of Duke Energy was working on a single-phase 120-/240-volt parallel service re-tap when a secondary flash occurred in an underground service. The employee suffered a second-degree burn to the face and was hospitalized.

Air-flo/Erwood Heating & Air Conditioning

An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.

Corrigan Brothers Inc

An employee was closing the side cargo door to a company van. The tip of his finger got caught between the door and the door jamb, resulting in a partial amputation.

Village Plumbing, Air & Electric

While working at a customer's residence, an employee was cutting tape with a box cutter to wrap insulation for a piece of pipe. The box cutter struck a hardened object within the wall causing it to bounce back and puncture the employee's right eye. The employee was hospitalized.

Goodrich Fire & Life Safety

An employee was assembling a baker type scaffold. He was beginning to transverse down the scaffold, approximately six feet off the ground, when the scaffold tipped over and he fell. The employee was hospitalized with a fractured femur.

Sprinklermatic Fire Protection Systems, Inc.

An employee was trimming out sprinklers on the exterior of a building when he fell off an extension ladder. He landed on the ground and sustained fractures to his nose and arm.

T G Meat Center LLC

After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.

Professional Flooring Supply

An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.

EnviroSafe Demil LLC

An employee was inspecting flares processes. The employee received burns to the front side of the body, face and arm from the flares.

Inteplast Group

An employee was removing plastic material from a production line when the machine cycled and amputated his left index, ring, and little fingers.

Regency IHS of Fairwinds Halletsville, LLC

An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.