Compressed or pinched by shifting objects or equipment · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at Auto Parts Manufacturing Mississippi, 100 Tab Way, GUNTOWN, MISSISSIPPI 38849
on — Amputations, affecting the finger(s), fingernail(s), n.e.c..
Final narrative
An employee was helping to adjust the alignment of a pneumatic cutter. The employee's right index finger was pinched between the cutter's cylinder and a spacer block attachment amputating two joints of the finger.
HospitalizedAmputationFinger(s), fingernail(s), n.e.c.Metal, woodworking, and special material machinery, unspecified
An employee was operating a forklift and unloading a truck. After the truck was unloaded, the employee got off the forklift and proceeded to adjust the dock plate with a hook tool. The dock plate slipped and the employee went to adjust the plate with their hand when their left middle finger got caught. Their finger was amputated above the first joint.
An employee was rotating a carbide granulator blade when his finger was caught between the blade and a stationary part of the machine. The employee's right middle finger was partially amputated and they suffered an avulsion to the right ring fingertip.
An employee was using a CNC metal lathe machine in manual mode to check that the thread blocking tool made contact with the jaws. As the employee was manually spinning the spindle, his index fingertip was crushed between the spindle's jaws and the grooving insert, resulting in a fingertip amputation.
During a material handling operation, an employee's fingertip was caught under an air conditioning unit as the unit was lowered onto a cart. The employee's fingertip was amputated.
An employee was removing a bolt from a tractor hub when their right index finger was caught between the hub and the frame. The employee's fingertip was crushed and the employee was hospitalized.
More severe injuries in this industry (NAICS 336370)
An employee was verifying light curtain function at a load cell tester when their right index finger was amputated by a hydraulic cylinder above the middle knuckle.
An employee was positioning an overhead crane to stand up a skidded coil when the coil swung back. The employee was caught between the swinging coil and another coil sitting on a coil pad, resulting in hospitalization due to a loss of consciousness and a pelvic injury.
An employee was performing general cleanup duties when they collapsed and passed out due to heat exhaustion. They were hospitalized for heat exhaustion, dehydration, and acute renal failure.
A temporary employee was helping a forklift operator by holding metal sheets to steady them as they were placed on a rail for feeding to a stamp machine. The operator lowered the forks with the blanks (weighting approximately 750 pounds). The temporary employee's right index finger was caught between the metal and the feeding rail. The finger was crushed and partially amputated through the bone.
An employee was using a mechanical trim press to trim flash off metal parts. The employee was loading a part to be trimmed when the press cycled and crushed the index fingers on both of their hands. The employee sustained a fingertip amputation. The machine was not guarded at the time.
An employee was checking a pole-type transformer tank for leaks. A hydraulic clamping device was lowered onto his right thumb and crushed it against the sharp edge of the bottom of the tank. He suffered a partial transphalangeal amputation to the thumb.
The injured employee was standing behind a table. She jumped out to scare another employee, but tripped and fell on the tile floor, injuring her right ankle/foot. She was hospitalized with a dislocated ankle that required surgery.
An employee was going into a trailer to mark product for shipment and the trailer pulled away from the dock. The employee fell out of the trailer, contacted the dock plate, and then fell to the ground. The employee was hospitalized with a punctured lung, fractured ribs, and contusions.
An employee was hooking up bundled tie-downs with a chain. While he was holding a hook, the other hook was unlocked. This caused the employee's hook to slide down and pinch his right index finger between the chain and the shackle. He suffered an amputation to the fingertip (without bone loss), as well as an open fracture.
An employee was operating a gas tugger to lift metal sheeting. His left hand was pulled into the pulley, which crushed his left thumb, resulting in avulsions and other tissue damage. He was hospitalized and required surgery.