105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Everglades Harvesting & Hauling, Inc

Direct exposure to electricity, unspecified · Electrical burns, unspecified

Federal OSHA recorded a severe workplace injury at Everglades Harvesting & Hauling, Inc, 1970 122nd Avenue, VERO BEACH, FLORIDA 32966 on — Electrical burns, unspecified, affecting the nonclassifiable.

While on a ladder picking oranges, an employee came into contact with a power line and suffered electrical burns.

Hospitalized Nonclassifiable Power lines, transformers, convertors

Everglades Harvesting & Hauling, Inc.

An employee was on a ladder trimming a tree when he slipped and fell from the ladder, landing on his back. He was hospitalized with a back injury.

View Everglades Harvesting & Hauling, Inc's full OSHA safety record →

Bob Woodall Air Care Systems, Inc.

An employee was installing a 15-amp breaker in an electrical panel when a 12-gauge ground wire touched the positive busbar of the panel, resulting in an arc flash. The employee sustained a second-degree burn to their left hand.

Amentum Spaceport LLC

An employee was repairing an HVAC system in the drop tile ceiling of a conference room when they were shocked, causing them to fall from the ladder. The employee sustained burns to their right middle and ring fingers.

Marsh Bellofram Corporation

An employee was replacing a contactor inside an electrical panel attached directly to a press. The press itself was receiving power from another main panel. After replacing the contactor, the employee flipped the switch and an arc flash occurred, burning the employee's elbow, bicep, and neck.

Heart Utilities of Jacksonville, Inc.

An employee was attempting to switch a medium-voltage primary cable and install a 200-amp fuse barrel. The employee contacted the bottom of the switch gear cradle for the fuse barrel, causing an arc blast. The electricity entered the employee s left hand and exited his big toes, resulting in electric shock and burns to the left hand, arm, shoulder, and both feet. The employee was hospitalized.

Duke Energy Florida, LLC

On December 6, 2023, an employee of Duke Energy was working on a single-phase 120-/240-volt parallel service re-tap when a secondary flash occurred in an underground service. The employee suffered a second-degree burn to the face and was hospitalized.

ALLEN E. SMITH RANCH & FARMING, INC.

An employee was operating an agricultural tractor when the tire was punctured and the tractor rolled over onto the employee. The employee was hospitalized with a fractured back and bruising to their heart and lungs.

Farmers Union Oil Co

An employee was filling the tire of a semi-trailer when the tire blew and contacted the employee, resulting in a fractured tibia.

Garden Remedies, Inc.

An employee was walking through the kitchen when they slipped and strained their lower back, resulting in hospitalization.

Bedner Growers

An employee was repairing an attic ladder on the second floor. The ladder opened, and employee fell through to the floor below. The employee was hospitalized with skull fractures, spinal fractures, and a spleen injury.

Corteva Agriscience

An employee was servicing a portable conveyor at a site and spun the pulley. The employee's fingertip was caught between the belt and the pulley, resulting in a fingertip amputation.

DRIFTWOOD NURSERY & LANDSCAPING, INC

An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.

Hobby Lobby Stores, Inc.

An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

Sugar Cane Growers Cooperative of Florida

An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.

Air-flo/Erwood Heating & Air Conditioning

An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.