An employee was operating a pneumatic bell press that had a two-hand trip. The employee attempted to adjust a part when the employee's finger was caught between the part and the point of operation, resulting in a right middle fingertip amputation. The machine was activated at the time of the incident.
At about 2:15 p.m. on February 10, 2025, employees were unloading pallets of propellant into a storage warehouse. The pallets were double stacked, and a top-loaded pallet had shifted in transit. Two employees were manually moving the pallet when the fiber packs shifted, causing one employee's left index finger to be pinched between the fiber pack and the pallet. The employee suffered a partial amputation to the fingertip.
A CNC operator was trying to replace a bearing in the hydraulically operated steadying fixture in a CNC machine. The fixture retracted, amputating the end of his right thumb.
An employee was changing an insert in the tool head of a CNC machine. The employee had stepped up approximately 28 inches onto the door track of the machine. When the employee went to step back down to the floor, they lost balance and fell backward onto a rack of metal parts. The employee sustained a compression fracture to the spine.
An employee was adjusting a switch on the loading cradle for a metal tracer lathe. The machine cycled, resulting in an amputation to the left index fingertip.
An employee was sharpening peeler blades when their shirt was caught in the grinding wheel. The employee sustained tendon damage and a crushed right hand.
An employee was preparing to cut lumber on a panel saw when the clamp engaged and caught the employee's left middle finger, resulting in a fingertip amputation.
More severe injuries in this industry (NAICS 332993)
An employee was working on a production line. The employee went to retrieve parts that came out of the parts holder, and their left hand became caught between a chain and a sprocket. Three fingers on the hand were amputated.
At about 2:15 p.m. on February 10, 2025, employees were unloading pallets of propellant into a storage warehouse. The pallets were double stacked, and a top-loaded pallet had shifted in transit. Two employees were manually moving the pallet when the fiber packs shifted, causing one employee's left index finger to be pinched between the fiber pack and the pallet. The employee suffered a partial amputation to the fingertip.
An employee was walking on the sidewalk near the administrative building when he slipped on ice and fell to the concrete ground. The employee suffered a left hip fracture and was hospitalized.
A CNC operator was trying to replace a bearing in the hydraulically operated steadying fixture in a CNC machine. The fixture retracted, amputating the end of his right thumb.
An employee was changing an insert in the tool head of a CNC machine. The employee had stepped up approximately 28 inches onto the door track of the machine. When the employee went to step back down to the floor, they lost balance and fell backward onto a rack of metal parts. The employee sustained a compression fracture to the spine.
An employee was changing a die in a press when the die slipped and crushed the employee's left index finger. The employee sustained an open facture of the tuft of the left distal phalanx and a partial amputation.
An employee was driving a boom lift (in the lowered position) in an exterior dock area. The lift s left wheels rolled onto base plates that covered a 3-foot-deep sump pit. The base plates failed, and one side of the lift dropped. The employee's left leg was caught under the lift basket, and he suffered a fracture to the lower leg including the ankle.