Struck, caught, or crushed in other collapsing structure or equipment · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Mundt Energy Services LLC, Weld County Roads 36 & 15, JOHNSTOWN, COLORADO 80534
on — Fractures, affecting the hip(s) and leg(s) .
Final narrative
Two employees were welding pipe when the 9x9 steel welding hut blew over due to a microburst. One employee was hospitalized for a fractured leg and hip.
An employee was reinserting a burner tube into a separator when his left index finger was caught between the tube and separator, amputation the top half-inch of his finger.
A mixer truck driver was delivering a load of concrete to a jobsite. The driver was operating the controls outside of his truck when a 6x10-foot fascia wall gave way. One of the concrete fascia panels struck the driver's right calf resulting in amputation of the leg below the knee.
An employee was receiving a 32-by-8 panel wall that weighed 3,500 pounds. As the crane was going up, the cable of one of the clanks became caught on the panel wall. The panel wall collapsed and struck the employee's right leg, resulting in right leg fractures and amputation below the knee.
An employee was moving conveyors in a warehouse to another location using rolling casters. The legs became detached from the bottom of the conveyor, and the employee's right index finger was caught in the conveyor pinch point, resulting in a fingertip amputation.
An employee had been cleaning the work area. While lifting a saw, the employee's index finger was lacerated by the saw blade. A tendon was cut and required surgery.
An employee was delivering home heating fuel when bees came from the ground and stung the employee's face, neck, torso, and hands. The employee proceeded to shut off the oil flow before losing consciousness. They were hospitalized due to an anaphylactic reaction.
An employee was using a torch to loosen a bolt on a water trailer. Natural gas was present in the water and it ignited, causing a fire. The employee sustained third-degree burns to their upper leg.
An employee had been conducting crane operations. The employee went to stop a piece of oil and gas equipment for tubular running from falling over to the ground. Their right hand was caught between a rolling ladder and the equipment, resulting in fractures to the index and middle fingers. They were hospitalized and the middle finger required surgery.
An employee was working to install a drive belt on a water pump. He was holding the belt on both sides of the pulley, working to route it over the top. As he pulled down with his right hand, the pulley rotated and the belt slid over it, pulling his left little finger between the pulley and the belt. He suffered an amputation to the fingertip as well as a fracture to the ring finger.
An employee was delivering materials. He was doing his pre-delivery inspection on the roof of the jobsite (a warehouse) when he fell through a plexiglass skylight. He landed on his feet on the concrete floor 14 feet below. The employee sustained fractures to his spine, left ulnar/radius, and right heel. The employee required surgery.
An employee was removing packaging from a roll of printing substrate. The blade of their utility knife got stuck. The employee used both hands to free the knife and the blade partially amputated their left little fingertip.
A concrete batch plant operator was assisting with clearing spoil piles using a skid steer. The skid steer backed into a stationary screen plant. The employee's left little finger was crushed between the controls of the skid steer and the screen plant, resulting in a fracture and laceration. The employee's finger was surgically amputated.