Caught in running equipment or machinery during regular operation · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at Plastics Design & Manufacturing, Inc, 6284 South Nome Ct , CENTENNIAL, COLORADO 80111
on — Amputations, affecting the fingertip(s).
Watch Plastics Design & Manufacturing, Inc — freeGet an email when a new federal OSHA severe-injury report for Plastics Design & Manufacturing, Inc is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was adjusting a screw on an air puncher machine. The machine activated and pinched the tip of his left index finger, amputating it.
AmputationFingertip(s)Metal, woodworking, and special material machinery, unspecified
An employee was sharpening peeler blades when their shirt was caught in the grinding wheel. The employee sustained tendon damage and a crushed right hand.
An employee was preparing to cut lumber on a panel saw when the clamp engaged and caught the employee's left middle finger, resulting in a fingertip amputation.
More severe injuries in this industry (NAICS 325211)
An employee was monitoring a rotary press when his left hand became caught in the machinery. The employee's left middle finger was amputated at the distal interphalangeal joint.
An employee was sweeping in an area with powdered PVC on the floor and began having difficulty breathing and coughing up blood, The employee was hospitalized for inhalation of PVC.
An employee was working on a pastillator machine, which processes resin-based materials into solid pastilles. His right hand became caught between the feed roller (operating at approximately 350 F) and the cooling belt. The employee s glove and shirt sleeve adhered to his arm due to the heat. The employee sustained third-degree burns to his right hand and forearm, requiring hospitalization and surgery.
An employee was troubleshooting a leak on a low pressure (less than 50 PSI) condensate line in the oxidation area of the plant. He was working to remove insulation around a valve when either the valve or the line failed, and hot condensate contacted his right arm, right abdomen area, and the front of both legs, resulting in second- and third-degree burns.
An employee was replacing a fan on a cooling unit. As he went to adjust a pump, the unit caught his right hand and the fan blades severely lacerated his index finger. He underwent a medical amputation to the finger.
An employee was delivering materials. He was doing his pre-delivery inspection on the roof of the jobsite (a warehouse) when he fell through a plexiglass skylight. He landed on his feet on the concrete floor 14 feet below. The employee sustained fractures to his spine, left ulnar/radius, and right heel. The employee required surgery.
An employee was removing packaging from a roll of printing substrate. The blade of their utility knife got stuck. The employee used both hands to free the knife and the blade partially amputated their left little fingertip.
A concrete batch plant operator was assisting with clearing spoil piles using a skid steer. The skid steer backed into a stationary screen plant. The employee's left little finger was crushed between the controls of the skid steer and the screen plant, resulting in a fracture and laceration. The employee's finger was surgically amputated.
An employee was standing on an extension ladder, using a torquing tool to remove bolts that secured blades to a rotor. When the torquing tool activated, its reaction arm came around and pinched the employee's right middle finger against a lifting eye. His fingertip was amputated.