105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

National Inspection Services, LLC

Exposure to environmental heat · Effects of heat and light, n.e.c.

Federal OSHA recorded a severe workplace injury at National Inspection Services, LLC, Swamp area, GEISMAR, LOUISIANA 70734 on — Effects of heat and light, n.e.c., affecting the bODY SYSTEMS.

An employee drove to a site to shoot wells with a non-radioactive source when the employee became dehydrated and experienced a heat injury.

Hospitalized BODY SYSTEMS Heat-environmental

View National Inspection Services, LLC's full OSHA safety record →

Great Northwest Concrete

An employee was performing finishing work on a residential driveway when they began to experience body cramps and were hospitalized for heat stress and dehydration.

Lady Moon Farms, Inc.

An employee was staking tomato plants on a farm. The employee began to feel sick and collapsed, suffering from dehydration and heat shock.

Federal Bureau of Investigation

An agent was participating in SWAT team selection and was performing various physical fitness skills including running and exercise intervals. The agent experienced dehydration and a muscular injury that required hospitalization.

Hi-Tech Roofing & Sheetmetal, Inc.

An employee was traveling back from work when they became ill and experienced dizziness due to heat exhaustion.

2911 Logistics

On September 26, 2023, an employee was delivering packages when he began to feel ill with a pain in his side. He was hospitalized for heat exhaustion and dehydration.

MAV-TEC Testing Laboratories, LLC

An employee was operating a horizontal belt sanding machine that rotates a metal sanding belt. The employee switched hands while the belt transitioned from left to right. When the machine's speed was adjusted, the employee s left hand was pulled into the machine and crushed. The employee was hospitalized and required surgery.

Boeing (LMTF)

An X-ray machine had lost power and an employee went to replace the power supply. While replacing a cable on the power supply assembly, the employee's right hand contacted the grounding terminals coming out of the back of the power supply assembly and they received an electric shock. The employee was hospitalized.

Cape Cod Healthcare Lab Services

On March 19, 2025, an employee was retrieving a medical specimen from the back of a vehicle. When he turned to enter the building, he either tripped over something or lost his footing and fell due to an incline in the pavement. The employee was hospitalized with a head abrasion and injuries to his right shoulder and right hip.

Agilent Technologies - Frederick, Colorado

Employees were pulling a chemical sample from a device (sample port). The sample wouldn't come out because there were two samples in the port. The employees then turned off and deenergized the machine to 0 pounds per square inch. They unscrewed the top of the machine to retrieve the stuck samples when a small amount of pressure caused liquid to squirt out and onto one of the employee's face shields as the lid was removed. The employee was hospitalized due to chemical exposure.

Applied Technical Services, LLC.

An employee was walking around a boiler recovery tank when they stepped into an uncovered U-drain filled with hot water. The employee sustained second-degree burns to their right leg and the top of their foot.

Kisatchie Midnight Express

A driver was exiting his vehicle outside the plant gate when his foot slipped on the top step of the truck. He fell to the ground, landed on his left hip and elbow. The employee was hospitalized with a fractured hip/femur.

CHRISTUS St. Frances Cabrini Hospital

A security employee was responding to an urgent call from staff regarding a violent patient. The employee tripped and fell on the floor outside of the stairwell. The employee sustained a closed head injury, contusion of the cerebrum without loss of consciousness, and a closed fracture of the distal end of the right radius.

Jean Simpson Personnel Services, Inc.

A temporary employee was testing an electrical starter motor. He was placing tape on the starter while the breaker was not engaged, but the starter sent an arc flash that burned his hands and stomach.

Calvary Industries Inc

An employee was walking on a sidewalk and stubbed his toe on an elevated portion of concrete, causing him to trip and fall. The employee's right knee was dislocated.