Fall through surface or existing opening, unspecified · Heat (thermal) burns, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at C K Enterprises Inc., 1920 Lacy Dr., JUNCTION CITY, KANSAS 66441
on — Heat (thermal) burns, unspecified, affecting the leg(s), unspecified.
Final narrative
An employee was walking from the pack floor to the stuff floor to run a hose through a location so that he could perform a cleaning duty. While he was walking over the clean-in-place (CIP) tank, the grating broke and he fell in. His left leg was burned. The CIP process was being run at the time, so it contained hot water and chemicals.
HospitalizedLeg(s), unspecifiedGrates and drains in floor surface
An employee was power washing a metal tank from an elevated platform. They fell through a gap between the platform and the tank. The employee landed on the ground and sustained fractures to their ankles and feet.
An employee was installing a metal roof when he stepped on a skylight. The employee fell through the skylight to the ground, resulting in head and shoulder fractures.
An employee was replacing an HVAC unit in a residential home. While he was in the attic space above the garage, the wood he was walking on broke, causing the employee to fall through the sheetrock to the concrete floor below. The employee bumped his head and sustained a shoulder injury as well as a broken ankle.
An employee was putting a tarp on a water tank while standing on a trailer. She lost her footing and fell through the trailer bed, striking the corner of the trailer bed. The employee sustained internal bleeding.
An employee was repairing a sub-floor in a residential house that had water and fire damage. The employee fell through the sub-floor and landed in the basement, resulting in spinal fractures that required hospitalization.
More severe injuries in this industry (NAICS 325199)
Two employees were lifting a roll of steel poly bar (50 inches and approximately 150 pounds) from ground level to a height of 4 feet at the 66-inch rubber calendar. One employee dropped the roll, resulting in the poly bar contacting the injured employee's right knee. The employee was hospitalized with fractured right patella.
Employees were loading a 295-pound transformer onto a pickup truck using a forklift. The injured employee was acting as the spotter. The transformer hit the tailgate of the pickup truck and the spotter's right hand was struck by the transformer, resulting in amputation of the ring fingertip.
An employee was wearing full PPE while emptying a 55-gallon drum of phosphorus pentoxide and fainted, collapsing and striking their head against the ground. The employee was hospitalized and it is likely that heat caused by wearing full body PPE contributed to fainting.
An employee was troubleshooting a plug in the super-absorbent polymer line. The employee opened an inspection port and their right hand was caught in a rotary valve, resulting in the amputation of four fingers between the knuckle and the first joint.
An employee was conducting a quality control measure by taking a chemical sample for lab analysis. When the employee was opening the sample point, it broke off and crude 2-Ethylhexyl thioglycolate (EHTG) shot out at 265 degrees, and it covered the employee's legs and right arm and splashed the right side of their face. The employee was hospitalized with first- and second-degree burns to their right thigh, lower right knee, inner left thigh, and upper left forearm.
An employee was working to remove a product blockage from a piece of equipment. The employee was struck by a metal bar near the deck of the pin mixer equipment and sustained blunt force trauma to the torso.
An employee was moving a rack onto a lower conveyor in the south heat treat area when their finger got caught between the part tray and the rollers, resulting in a fingertip fracture and amputation.
An employee was climbing a ladder to get on top of the breakroom. The ladder slipped, causing him to fall to the ground. The employee sustained fractures to his upper back, left foot, and ankle.
Two employees were removing a circuit breaker. The injured employee was using wrenches in the removal process. One of the wrenches contacted an adjacent door, resulting in an arc flash. The employee suffered burns to their neck, face, and ear, as well as momentary vision loss due to the flash.
An employee bent over to pick up a rubber mat from the ground. When he grabbed the corner of the mat, a rattlesnake hidden under it bit his left middle finger near the first knuckle. He was hospitalized.