National Beef Packing Co. LLC.

Caught in or compressed by equipment or objects, unspecified · Amputations

Federal OSHA recorded a severe workplace injury at National Beef Packing Co. LLC., 2000 E. Trail St., DODGE CITY, KANSAS 67801 on — Amputations, affecting the finger(s), fingernail(s), n.e.c..

An employee was replacing a chain when their finger got caught in a chain hole. The chain then moved and crushed the employee's finger resulting in amputation of the right index finger.

Hospitalized Amputation Finger(s), fingernail(s), n.e.c. Chains, n.e.c.

National Beef Packing Co., LLC

An employee was walking alongside a conveyor when she stepped on a conduit on the ground, causing her to slip and fall onto the conveyor belt. She was hospitalized with bruised and fractured ribs.

National Beef Packing Co LLC

An employee was driving a forklift out of a freezer. The forklift slid into a bin, and the employee's right index finger was broken.

National Beef Packing Co LLC

An employee was walking when they slipped and hit their face on a metal container, resulting in a fractured jaw.

National Beef Packing Co LLC

An employee suffered chemical burns while changing sulfuric acid and was hospitalized.

National Beef Packing Co LLC

An employee was unclogging a drain with a water hose when it backwashed on him. There was residue of a cleaning agent in the drain that caused burns to his arms, right knee, face, and eyes.

View National Beef Packing Co. LLC.'s full OSHA safety record →

N. S. Giles Foundations, Inc.

An employee was changing mud cups in the hopper cylinders of a concrete pump truck. The cylinders moved and three of the employees fingers were amputated.

Weld Mech, Inc.

An employee was standing on the rig floor next to a polishing unit. His hand was placed on the polishing unit when the pump was lowered, resulting in amputation of their right thumb, ring, and middle fingertips.

Axium Packaging LLC

An employee was using air to blow out the air wash to the blender and grinder station. As the employee reached to verify that the air wash was clean, the unit pinched and amputated their fingertip.

PanTerra Energy

An employee was retrieving a lost drill pipe with a lifting bail when their left thumb got pinched between the table and handle of the lifting bail while trying to re-thread the pipe to lift it out. The employee suffered an amputation to the left thumb.

Graphic Packaging International

An employee was removing a core chuck from a stationary roll when their right ring finger was pinched between the chuck and the roll. The employee's fingertip was amputated.

Ruprecht Company dba Kilcoy Global Foods

A temporary employee was working to unclog butter from a butter melter pump. His right index finger was caught in the machine, and the fingertip was amputated. The machine was energized at the time.

Fieldale Farms Corporation

An employee working at the reject conveyor was placing a product guide bar on the conveyor. This metal guide bar is placed on the side of the conveyor belt to funnel the product, preventing it from falling off the sides. As he was getting the attachment positioned, his left ring finger was caught between the conveyor belt and the conveyor belt frame. The employee's finger was fractured and partially amputated.

Dakota Protein Solutions, LLC

An employee was using a pneumatic impact wrench to tighten bolts on a brake press anvil. The impact wrench hooked up on something, causing the tool to rotate. This spun his left hand with it. Their index finger was pinched between the side handle of the tool and an anvil bolt on the press, resulting in an open fracture. The employee required a medical amputation of the fingertip.

True West Beef

An employee was cleaning the area under a mobile elevated work platform. The platform lowered and struck the employee, resulting in a fractured right femur. The employee was hospitalized.

Sanimax USA LLC

As an employee was opening an infeed valve. Hot tallow oil in the line above fell back down the pipe and came out of an open pressure relief valve, striking the employee on the thighs. The employee was hospitalized with second-degree burns to his thigh. Another employee sustained burns to their back but they were not hospitalized.

Omya Inc.

An employee was working to remove a product blockage from a piece of equipment. The employee was struck by a metal bar near the deck of the pin mixer equipment and sustained blunt force trauma to the torso.

John Deere Coffeyville Works

An employee was moving a rack onto a lower conveyor in the south heat treat area when their finger got caught between the part tray and the rollers, resulting in a fingertip fracture and amputation.

Haven Steel Products Inc

An employee was climbing a ladder to get on top of the breakroom. The ladder slipped, causing him to fall to the ground. The employee sustained fractures to his upper back, left foot, and ankle.

Vestas-American Wind Tech

Two employees were removing a circuit breaker. The injured employee was using wrenches in the removal process. One of the wrenches contacted an adjacent door, resulting in an arc flash. The employee suffered burns to their neck, face, and ear, as well as momentary vision loss due to the flash.

Alliance Ag and Grain LLC

An employee bent over to pick up a rubber mat from the ground. When he grabbed the corner of the mat, a rattlesnake hidden under it bit his left middle finger near the first knuckle. He was hospitalized.