105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

INVENERGY SERVICES LLC

Direct exposure to electricity, unspecified · Electrical burns, unspecified

Federal OSHA recorded a severe workplace injury at INVENERGY SERVICES LLC , Camp Springs Energy Center, SNYDER, TEXAS 79549 on — Electrical burns, unspecified, affecting the hand(s), unspecified.

An employee was replacing a converter box in a wind tower. He contacted an electrical line and suffered burns to the left hand. He was hospitalized.

Hospitalized Hand(s), unspecified Electric parts, unspecified

Invenergy Services LLC

An employee was cleaning dirt out of a contactor using a hand-held blower and contact cleaner. An arc flash occurred, and the employee sustained burns to the right side of their face and both hands.

Invenergy Services LLC

An employee was turning off a lever-style breaker in a wind turbine when an arc flash occurred. The employee was hospitalized with burns to the right hand.

View INVENERGY SERVICES LLC 's full OSHA safety record →

Bob Woodall Air Care Systems, Inc.

An employee was installing a 15-amp breaker in an electrical panel when a 12-gauge ground wire touched the positive busbar of the panel, resulting in an arc flash. The employee sustained a second-degree burn to their left hand.

Amentum Spaceport LLC

An employee was repairing an HVAC system in the drop tile ceiling of a conference room when they were shocked, causing them to fall from the ladder. The employee sustained burns to their right middle and ring fingers.

Marsh Bellofram Corporation

An employee was replacing a contactor inside an electrical panel attached directly to a press. The press itself was receiving power from another main panel. After replacing the contactor, the employee flipped the switch and an arc flash occurred, burning the employee's elbow, bicep, and neck.

Heart Utilities of Jacksonville, Inc.

An employee was attempting to switch a medium-voltage primary cable and install a 200-amp fuse barrel. The employee contacted the bottom of the switch gear cradle for the fuse barrel, causing an arc blast. The electricity entered the employee s left hand and exited his big toes, resulting in electric shock and burns to the left hand, arm, shoulder, and both feet. The employee was hospitalized.

Duke Energy Florida, LLC

On December 6, 2023, an employee of Duke Energy was working on a single-phase 120-/240-volt parallel service re-tap when a secondary flash occurred in an underground service. The employee suffered a second-degree burn to the face and was hospitalized.

Vestas-American Wind Tech

Two employees were removing a circuit breaker. The injured employee was using wrenches in the removal process. One of the wrenches contacted an adjacent door, resulting in an arc flash. The employee suffered burns to their neck, face, and ear, as well as momentary vision loss due to the flash.

Spark Power Corp

An employee was ascending the wind tower when their right arm was caught between the lift and the ladder. The employee sustained a right elbow injury and was hospitalized.

Acciona Energy North America Corporation

On 3/27/2025, at 9:57 AM, an employee was performing switching work including installing electrical grounds when an arc flash occurred. Personal protective equipment (PPE) was worn at the time, including an arc flash hood, shirt, and pants. The employee suffered burns and was hospitalized.

Invenergy Services LLC

An employee was cleaning dirt out of a contactor using a hand-held blower and contact cleaner. An arc flash occurred, and the employee sustained burns to the right side of their face and both hands.

GD Energy Services - Wind, Inc.

On February 16, 2025, an employee was descending a ladder on the third deck after completing rigging at a wind farm. Their left foot slipped on the penultimate rung and their leg became wedged between the ladder rungs and a horizontal bracket. The employee then landed on the second deck resting platform, resulting in a leg fracture above the ankle.

T G Meat Center LLC

After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.

Professional Flooring Supply

An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.

EnviroSafe Demil LLC

An employee was inspecting flares processes. The employee received burns to the front side of the body, face and arm from the flares.

Inteplast Group

An employee was removing plastic material from a production line when the machine cycled and amputated his left index, ring, and little fingers.

Regency IHS of Fairwinds Halletsville, LLC

An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.