105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Quinn Group, Inc.

Direct exposure to electricity, unspecified · Electrical burns, unspecified

Federal OSHA recorded a severe workplace injury at Quinn Group, Inc., 1020 Soboba Road, SAN JACINTO, CALIFORNIA 92583 on — Electrical burns, unspecified, affecting the multiple body parts, n.e.c..

An employee was drilling an electrical cover when the employee contacted live electrical wires and an arc flash occurred. The employee sustained burn injuries to the face and right hand/arm.

Hospitalized Multiple body parts, n.e.c. Switchboards, switches, fuses

Bob Woodall Air Care Systems, Inc.

An employee was installing a 15-amp breaker in an electrical panel when a 12-gauge ground wire touched the positive busbar of the panel, resulting in an arc flash. The employee sustained a second-degree burn to their left hand.

Amentum Spaceport LLC

An employee was repairing an HVAC system in the drop tile ceiling of a conference room when they were shocked, causing them to fall from the ladder. The employee sustained burns to their right middle and ring fingers.

Marsh Bellofram Corporation

An employee was replacing a contactor inside an electrical panel attached directly to a press. The press itself was receiving power from another main panel. After replacing the contactor, the employee flipped the switch and an arc flash occurred, burning the employee's elbow, bicep, and neck.

Heart Utilities of Jacksonville, Inc.

An employee was attempting to switch a medium-voltage primary cable and install a 200-amp fuse barrel. The employee contacted the bottom of the switch gear cradle for the fuse barrel, causing an arc blast. The electricity entered the employee s left hand and exited his big toes, resulting in electric shock and burns to the left hand, arm, shoulder, and both feet. The employee was hospitalized.

Duke Energy Florida, LLC

On December 6, 2023, an employee of Duke Energy was working on a single-phase 120-/240-volt parallel service re-tap when a secondary flash occurred in an underground service. The employee suffered a second-degree burn to the face and was hospitalized.

NATIONAL MILL MAINTENANCE, LLC

An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.

Elkhorn Mechanical and Combustion

An employee was climbing a ladder to inspect a vent in a restaurant dining area. The ladder slid out on the floor and the employee fell approximately 12 feet onto the ladder and the floor. He was hospitalized with a dislocated shoulder and a back injury.

Crown Lift Trucks

An employee was operating a lift truck when it struck a stationary lift truck. His left thumb was pinched between the two lift trucks, resulting in a partial amputation.

Spellman High Voltage Electronics Corporation - Valhalla

An employee was disassembling a pressurized unit using a driver drill. When the unit was disassembled, it caused a kickback from the tube head, causing the drill to strike the employee's left forearm. They sustained a diaphyseal fracture to their left radius and ulna, which required surgery.

Ring Power Corporation

After repairing a piece of industrial equipment, an employee had brake-cleaning liquid on his gloves. A lighter ignited the liquid, and the employee's hands were severely burned.

Department of Justice - USMS

The injured employee was assisting a Department of Homeland Security (DHS) enforcement operation. During an apprehension, officers returned fire at a subject and struck the employee with a bullet. The employee sustained a gunshot wound to their right hand.

M1 Support Services

The injured employee was assisting in the disassembly phase after a radar array had been lowered and secured. The crew began removing load bearing pins from an overhead crane to free the radome. A load bearing pin was stuck. The injured employee went to remove the pin manually as a second team member applied pressure from the opposite side. The pin unexpectedly released and struck the injured employee s right thumb, resulting in partial amputation of the distal phalanx including an open distal phalanx fracture and nail bed laceration.

Dept. of Defense - USN

An employee was working on an electrical panel in a mechanical room when an arc flash occurred. The employee suffered burns.

Dept. of Homeland Security - CBP

At about 3:10 p.m. on October 3, 2025, an employee was inspecting a car. Two dogs that had been in another car were leashed and tethered to a bollard. As the employee inspected the first car along with a narcotics detection dog, one of the other dogs came loose and attacked the narcotics dog. The employee was separating the dogs when the other dog bit his left ring finger. The last joint of the finger was injured and part of it was bitten off.

Sycuan Casino Resort

An employee was preparing a bundle of green onions for chopping. While holding the bundle in his left hand, he made his first cut using a 9-inch kitchen knife held in his right hand. The knife contacted the tip of his left thumb, resulting in an amputation of approximately 0.5 inches of the thumb that required hospitalization.