Direct exposure to electricity, greater than 220 volts · Electrical burns, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Bowman Steel, LLC, Midtown West Tower Project, TAMPA, FLORIDA 33607
on — Electrical burns, unspecified, affecting the face, unspecified.
Final narrative
An employee was descending from the third floor deck in an aerial lift and made contact with a 69-Kv power line. The employee sustained flash burns to the face.
An employee was attaching a steel angle plate weighing (approximately 200 pounds) to the end of a structural member (5,000 pounds) and was supported by dunnage. The dunnage was a crane mat (11 inches tall) with a 4x6 board on top of it and it supported five identical members. The main piece was 30.75 feet long, 37.25 feet tall, and 1 food wide. As the employee slid the piece of metal on top of the member to begin attaching it, the entire member began to tip over. The employee went to stop the main piece from tipping over and it landed on his ankle, fracturing it.
An employee was using a cordless impact drill to drill a hole in a column plate when the drill bit became stuck in the hole. The drill spun around and amputated the employee's left little fingertip.
An employee was installing a ground wire to a power transmission pole. The ground wire contacted an energized portion of a cut-out, causing an arc-flash. The employee was hospitalized with second degree burns to their chest and arms.
An employee was connecting a utility transformer for underground service to a home. The employee's impact drill went across two connection bars with 240 volts of potential, creating an arc flash. The employee sustained burns to the face and eyes due to the arc flash and molten aluminum.
On December 15, 2023, at 9:15 AM, an employee was changing 60-amp fuses in a 480-volt panel when an arc flash occurred. The employee was hospitalized with burns to both hands.
An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.
An employee was attempting to lift a steel beam from a horizontal, stacked position to a vertical position using a crane. They had placed two hooks on the east side of the beam on the flange. As the employee was hoisting the crane, the beam began to shift and pulled the employee forward onto the stack. When the material shifted, the hooks released and the material fell, pinning the employee between the two beams. The employee was hospitalized with soft tissue contusions on their proximal right thigh and interior left thigh.
An employee was standing on the surface of a steel beam about two feet wide. He slipped and fell backward, landing on the concrete ground about 20 feet below. The employee sustained a broken pelvis.
An employee was unloading a rebar delivery from a flatbed, 19-wheel trailer. The employee rigged the load with wire rope chokers. The load was picked up 3-4 feet above the trailer deck by a crane. The load began to swing and the employee grabbed onto it to prevent it from being pushed off the trailer deck. The crane continued to lift the load, and the employee let go so the crane did not lift him to the third story. The employee fell approximately 12 feet to the ground below, resulting in a back injury and fractured vertebrae.
An employee was attaching a steel angle plate weighing (approximately 200 pounds) to the end of a structural member (5,000 pounds) and was supported by dunnage. The dunnage was a crane mat (11 inches tall) with a 4x6 board on top of it and it supported five identical members. The main piece was 30.75 feet long, 37.25 feet tall, and 1 food wide. As the employee slid the piece of metal on top of the member to begin attaching it, the entire member began to tip over. The employee went to stop the main piece from tipping over and it landed on his ankle, fracturing it.
An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.
An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.
An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.
An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.