Caught in running equipment or machinery during regular operation · Internal injuries to organs and blood vessels of the trunk
At a glance
Federal OSHA recorded a severe workplace injury
at JDJ Operations, LLC, 222 Industrial Drive, MOULTRIE, GEORGIA 31788
on — Internal injuries to organs and blood vessels of the trunk, affecting the chest, except internal location of diseases or disorders.
Final narrative
When an employee turned the control on the robotic extruder machine to auto the sensor on the gate malfunctioned and allowed the robot to operate. The robot swung and hit the employee on the right side causing broken ribs and a punctured lung.
HospitalizedChest, except internal location of diseases or disordersExtruding machinery
An employee was sharpening peeler blades when their shirt was caught in the grinding wheel. The employee sustained tendon damage and a crushed right hand.
An employee was preparing to cut lumber on a panel saw when the clamp engaged and caught the employee's left middle finger, resulting in a fingertip amputation.
More severe injuries in this industry (NAICS 331521)
An employee was trimming manufactured parts using a two-hand control, C-frame trim press. They were manipulating parts in the machine when their hand contacted the controls that energized the machine. The employee sustained amputations to their left index finger and left thumb.
Two employees were operating an aluminum die casting machine when a piston that pushed molten aluminum into the mold stopped dispensing aluminum correctly. After they had spent several hours fixing the issue, the machine cycled and the die closed on one employee's right hand. The employee suffered amputations to the index fingertip and the thumb at the knuckle.
An employee was operating a mold machine when a pouring ladle that was coated with a water-based paste was submerged in molten aluminum. The moisture caused an explosion, resulting in severe burns over his body.
On September 10, 2024, at approximately 5:55 AM, an employee suffered burns to his right hand as he was removing a ladle from a furnace and the cup made contact with the side of the furnace, splashing molten aluminum into his glove. The employee was hospitalized with burns to his right hand.
An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.
During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.
An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.