Caught in running equipment or machinery during maintenance, cleaning · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at ADVANCED AIRFOIL COMPONENTS LLC, 13111 BAY INDUSTRIAL DR., GIBSONTON, FLORIDA 33534
on — Amputations, affecting the fingertip(s).
Final narrative
An employee was cleaning a large pot used for mixing compounds for coating shell work when his left pinky finger was struck by a moving part that rotates inside the pot, resulting in a partial amputation of the pinky fingertip.
AmputationFingertip(s)Painting, priming, metal coating machinery
More severe injuries at ADVANCED AIRFOIL COMPONENTS LLC
An employee began moving a cart with a ceramic mold on top of it when the mold fell off the cart and smashed the employee's left hand, resulting in a broken middle finger.
Two employees were repairing the hydraulic engagement pins on a rented front-end wheel loader. The machine controls were activated to move the attachment pins and an employee's finger was caught between the pins and the bushings. Their right index finger was partially amputated.
An employee was cleaning the conveyor on a piece of equipment when they slipped and their right hand was pulled into the chain sprocket. The employee's fifth fingertip was amputated.
An employee was throwing blankets onto a blanket folding and stacking machine. A blanket got stuck in the machine and she attempted to remove it when the machine contacted her right little finger, resulting in a fingertip amputation.
More severe injuries in this industry (NAICS 333611)
Four employees were traveling in a utility task vehicle (UTV) on the east lot of the site. While turning, the UTV flipped over onto the driver's side. The driver's left wrist and hand were crushed by the frame of the UTV resulting in a fractured and dislocated wrist, as well as hand injuries. The driver was hospitalized and required surgery.
On August 15th, 2025, an employee was aligning/connecting a coupler to the generator of a wind turbine. The coupler was secured in place by a strap that was connected to the turbine's chain hoist and a bolt. While lining up the remaining holes, the coupler rotated while the employee's right index finger was in one of the bolt holes, causing a partial amputation through the phalanx.
Employees were preparing to unload a wind turbine gearbox from a flatbed trailer. An employee went to reposition himself on the flatbed trailer and grabbed onto a wooden piece of the shipping cribbing for support. The piece of wood began to come loose, causing the employee to lose his balance. The employee jumped to the ground about 4 feet below and landed on his feet. His left ankle rolled and the employee was hospitalized with a fractured ankle that required surgery.
An employee was working to move a paper roller carriage, which is a 3 by 3-foot paper roll weighing approximately 500 pounds. The employee's hands were positioned in the area where the spool meets the cradle. As the employee moved the carriage across a floor track, the paper roll was dislodged and caught the employee's finger, severing it. The employee's right middle fingertip was partially amputated.
An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.
An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.
An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.
An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.