An employee was troubleshooting a filling station that was overfilling tubes of product. The overflow on the crimpers was getting onto the outer tubing/packaging. The employee went to wipe product from the number three crimp and the machine cycled, catching the employee's right hand. The employee's right middle finger was amputated just above the first knuckle. A guard was in place at the time.
On December 19, 2023, an employee was setting up a copper wire drawing machine when his left ring finger was pinched between a copper wire and a machine part. The employee's finger was partially amputated.
An employee was checking the gusset seal on a machine. He moved to the next cross sealer and the machine activated, causing an amputation to a left-hand finger. The employee was hospitalized.
An employee was evaluating a coiling machine to verify that the blade was present inside it. The machine's weld function was activated, and the machine crushed the employee's fingers, resulting in the amputation of the left middle and ring fingers.
An employee was on a ladder disconnecting a 1-inch hose, known to have last carried acrylic acid that had been drained. When the hose was disconnected, residual acid dripped onto the employee's shoulder/arm area, causing a second-degree chemical burn.
On October 1, 2025, at approximately 9:50 p.m., an employee was removing a sack of debris from a dust collector when four of his right-hand fingers were severed by a rotary valve. The employee was hospitalized and underwent surgery to amputate the four fingers at the knuckle.
An employee was unloading and depressurizing a railcar filled with sulfuric acid. The employee turned the valve to disconnect the hose when sulfuric acid released and sprayed upward via the standpipe. The employee was hospitalized burns.
On May 8, 2025, an employee developed a cough while cleaning up chemical sewage from the floor. He was hospitalized, having suffered an allergic reaction to chemical product vapors.
An employee was loading a magazine of tubes into a machine to fill. As they raised the door into position, the door dropped onto the employee's right hand and amputated their right index fingertip at the nailbed.
An employee was working to deliver mail to an apartment building. She was waiting for a customer to move, to obtain clearance to the mailboxes. The door swung inward and closed on her right little finger. The top half of her finger was surgically amputated.
An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.