105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Affordable Tree Service of Ct

Indirect exposure to electricity, greater than 220 volts · Electrical burns, unspecified

Federal OSHA recorded a severe workplace injury at Affordable Tree Service of Ct, 160 Oak Street, WINSTED, CONNECTICUT 06098 on — Electrical burns, unspecified, affecting the upper and lower limb(s).

An employee was in a tree, trying to attach a crane cable to it. When he reached for the crane cable, he was shocked, because the crane boom had come into contact with overhead power lines. He suffered burns to the left hand and left foot and lost consciousness for about 30 seconds.

Hospitalized Upper and lower limb(s) Cranes, unspecified

Lott Brothers Construction Company LTD

A crew was working near an electrical pole. A co-worker was using a front-loader to grade a slope when the loader slid into a guy-wire and became tangled and stuck. The injured employee used a handheld grinder to cut the wire a few feet from the ground. The lower part of the wire fell to the ground, but the upper part of the wire fell toward the pole and contacted an energized part before the end landed in nearby bushes. The employee attempted to shake the bush to free the wire so it could fall back toward the pole. The wire popped up and contacted his hands, resulting in electrical entry burns to both hands and exit burns on both feet.

Quality Service Team, LLC

On November 18, 2023, two employees were using a 2x4 to lift a power line. The boom lift they were operating made contact with power lines and both employees sustained electrical shock injuries.

Jemez Mountains Electric Co-Op, Inc

An employee was part of a crew that was servicing a power line. The employee was in a bucket truck when he contacted the 7,200-volt power line. The electricity entered through one hand and exited the other, causing several electrical burns. The employee was not wearing proper personal protective equipment at the time.

Commonwealth Edison Company

An employee was helping a crew set up a 45-foot pole between two other poles. It was being set up between two energized lines and the pole made contact with the A-phase. The employee was electrocuted and lost consciousness. The electricity also caused an entry wound in their left forearm and an exit wound in their left foot.

CJE Rebar Corp

An employee was handling a 45-foot long rebar for installation on the third floor of a building at a 30-foot elevation. The rebar came into close proximity of a powerline situated 13 feet off the building. The employee sustained electrical burns to his hands from electric discharge, requiring hospitalization.

Garden Angels New York LLC

An employee was cleaning leaves with a backpack blower when he fell from a ladder, resulting in injuries to his head, neck, and back.

Advanced Mulch Inc

An employee was helping to set up a mulch blowing truck when they were struck by an oncoming vehicle. The employee was hospitalized with a fractured knee, a concussion, and a head laceration; they also received stitches on their arm.

4 Seasons Property Services, Inc.

An employee was rappelling down a tree. When he was most of the way down, he fell on the ground and suffered a broken pelvis.

Boston Land Co Management Services Inc

An employee was using a table saw to cut a piece of wood when the saw cut his thumb, index, and middle fingers. His index finger was amputated and he was hospitalized.

Parm's Landscape Management

An employee was mowing a residential lawn at a client's house. The mower slid on the land and tipped over onto him. The employee was hospitalized with a fractured vertebra in the neck and partial paralysis.

Heavy Weight Inc

An employee was checking on a machine outside of the building and removed a cover to clean out a blocked area. His hand was caught by a rotary valve in a dust collection machine. The employee's fingertip was amputated.

Duro Bag

An employee was working to clean a glue roller with a scraper tool. The tool and the employee's left thumb were pinched between two rollers, resulting in a partial amputation.

United Refrigeration Inc

An employee was re-arranging boxes of pipe insulation on a pallet. One of the boxes fell from the pallet and knocked over an upright empty cylinder. The cylinder fell and crushed the tip of the employee's right toe. The employee's toe required surgical amputation.

Michels Power, Inc.

An employee was securing the claw of a grapple truck to the truck bed. His left little finger was caught between the tie down strap and the rub rail of the truck, resulting in partial amputation of the finger.

Parker-Hannifin Corporation

An employee was cutting extruded aluminum framing material using a horizontal band saw. She went to grab a rag in the machine when the rag contacted the blade and pulled her hand in toward the blade, resulting in a partial amputation of the right index finger.