Caught in running equipment or machinery, n.e.c. · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at Emery Oleochemicals LLC, 4900 Este Ave, CINCINNATI, OHIO 45232
on — Amputations, affecting the fingertip(s).
Final narrative
An employee was inspecting a rotary air lock valve when their right hand contacted the valve, resulting in fingertip amputations.
HospitalizedAmputationFingertip(s)Special process machinery, n.e.c.
Employees were assembling and testing a butterfly valve unit and actuator combo. When the unit was function tested with air, the valve gate closed on an employee's left thumb resulting in a fracture and laceration.
An employee was doing a daily inspection of the sifter screen on a mixer when the mixer line activated. The armature for the screen struck the employee's right wrist. Their wrist was cut and their hand was fractured.
An employee was doing a dry run during the setup of an ice cream machine. The machine indexed and the filler head amputated the employee's left middle finger above the last knuckle.
An employee was on a 3-foot ladder guiding cable onto a spool during installation on an overhead door. As the control box was jogged, the employee's hand was caught between the cable and spool, resulting in a wrist and hand fracture.
More severe injuries in this industry (NAICS 325199)
Two employees were lifting a roll of steel poly bar (50 inches and approximately 150 pounds) from ground level to a height of 4 feet at the 66-inch rubber calendar. One employee dropped the roll, resulting in the poly bar contacting the injured employee's right knee. The employee was hospitalized with fractured right patella.
Employees were loading a 295-pound transformer onto a pickup truck using a forklift. The injured employee was acting as the spotter. The transformer hit the tailgate of the pickup truck and the spotter's right hand was struck by the transformer, resulting in amputation of the ring fingertip.
An employee was wearing full PPE while emptying a 55-gallon drum of phosphorus pentoxide and fainted, collapsing and striking their head against the ground. The employee was hospitalized and it is likely that heat caused by wearing full body PPE contributed to fainting.
An employee was troubleshooting a plug in the super-absorbent polymer line. The employee opened an inspection port and their right hand was caught in a rotary valve, resulting in the amputation of four fingers between the knuckle and the first joint.
An employee was conducting a quality control measure by taking a chemical sample for lab analysis. When the employee was opening the sample point, it broke off and crude 2-Ethylhexyl thioglycolate (EHTG) shot out at 265 degrees, and it covered the employee's legs and right arm and splashed the right side of their face. The employee was hospitalized with first- and second-degree burns to their right thigh, lower right knee, inner left thigh, and upper left forearm.
An employee was working to deliver mail to an apartment building. She was waiting for a customer to move, to obtain clearance to the mailboxes. The door swung inward and closed on her right little finger. The top half of her finger was surgically amputated.
An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.