Caught in running equipment or machinery during maintenance, cleaning · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at American Castings, LLC, 5265 Hunt Street, PRYOR, OKLAHOMA 74361
on — Amputations, affecting the fingertip(s).
Final narrative
An employee was cleaning sand off the rollover stop block on a molding machine. His right middle fingertip was crushed, necessitating a surgical amputation.
An employee noticed a block was out of place under the weighted mold frame. The employee used another block to push the block out and replace it. When the block came out, the frame came down on his right ring and little fingers. The employee sustained a fracture and partial amputation to the ring fingertip.
An employee was walking back to his work area after dumping a trash can into a hopper when a forklift backed up onto the employee's left foot and fractured it.
Two employees were repairing the hydraulic engagement pins on a rented front-end wheel loader. The machine controls were activated to move the attachment pins and an employee's finger was caught between the pins and the bushings. Their right index finger was partially amputated.
An employee was cleaning the conveyor on a piece of equipment when they slipped and their right hand was pulled into the chain sprocket. The employee's fifth fingertip was amputated.
An employee was throwing blankets onto a blanket folding and stacking machine. A blanket got stuck in the machine and she attempted to remove it when the machine contacted her right little finger, resulting in a fingertip amputation.
More severe injuries in this industry (NAICS 331511)
An employee was realigning two halves of a core box on a core-making machine. Pneumatic pressure released, causing the core box to close on the employee's right thumb. The thumb tip was amputated between the nail and the knuckle.
An employee was performing maintenance/electrical work inside a substation, and used a ladder to access the top of a panel box. The employee fell 8-9 feet from the top of the panel box to the ground. The employee was hospitalized with fractures to their ribs and a shoulder injury.
An employee's hand was caught in a pinch point in the area of a conveyor for a flask running out of a foundry molding machine. The employee's ring finger was crushed and partially amputated at the base.
An employee noticed a block was out of place under the weighted mold frame. The employee used another block to push the block out and replace it. When the block came out, the frame came down on his right ring and little fingers. The employee sustained a fracture and partial amputation to the ring fingertip.
An employee was using a fork truck to move a tub containing molten iron that had been drained from the cupula. The tub tipped over and the molten metal came in contact with water. This caused the molten iron to splash back and burn the employee's upper torso.
An employee was helping to move a 1,300-pound coil on a cart. The steel caster hit a crack in the concrete, the weld holding the caster onto the cart broke, and the coil and cart tipped over onto the employee. He was hospitalized with a laceration on his forehead and a pelvic fracture on his right side.
An employee was working in the food service warehouse when he experienced chest pain, difficulty breathing, and lost consciousness. The employee sustained carbon monoxide poisoning.
An employee was cutting a piece of metal rod with a metal cutting machine. His right middle finger became caught between the rod and the machine's table. The employee's fingertip was partially amputated.
An employee was working at her desk. She went to stand up and fell to the floor beside the desk. The employee sustained a hip displacement and required surgery.
An employee was processing wood boards at a chop saw when the saw malfunctioned and the blade cut her left hand and fingers. She was hospitalized and her little finger was surgically amputated.