Ignition of vapors, gases, or liquids · Heat (thermal) burns, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Long's Propane Service Inc., 2910 East Highway 50, YANKTON, SOUTH DAKOTA 57078
on — Heat (thermal) burns, unspecified, affecting the multiple body parts, n.e.c..
Watch Long's Propane Service Inc. — freeGet an email when a new federal OSHA severe-injury report for Long's Propane Service Inc. is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was preparing 1000-pound tank for painting. When a valve was removed it released propane into the shop environment where ignition sources started a fire that burned down the shop. The employee sustained burns to their hands and face.
An employee was cleaning a cordless drill. As they applied brake fluid to the drill and pulled the trigger, the fluid ignited. The employee suffered burns to the face, hands, and arms.
An employee was spraying glue to the floor of an enclosed cargo trailer. The fumes made contact with the heater causing a flash fire. The employee suffered burns to their face and right hand.
An employee was replacing a valve in the gas line to the fryer. The shutoff valve malfunctioned resulting in a gas leak that then ignited. The employee sustained burns requiring hospitalization.
An employee was connecting a hose to fill a propane cylinder. The flow of propane was activated when the filler nozzle was partially connected to the cylinder. The nozzle detached from the cylinder valve, causing expanding liquid propane to release through the nozzle. This caused the employee to lose his balance, spin, become entangled in the hose, and fall. He struck his head on the ground and suffered fractures to the temple and cheekbones, a laceration on the forehead, and a brain bleed. The employee was hospitalized.
An employee was filling a motor fuel cylinder from a bobtail. When he opened the handle on the fill nozzle it popped off the filler valve and pushed him back into a rack where he struck his head on a cylinder cage. He sustained a laceration to the back left side of his head. While working to wrestle the hose to the ground, he sustained burns from liquid propane on the right side of his chest and right arm, and sustained minor burns on the left side.
An employee had been refueling empty propane tanks at a site. He drove back to the bulk plant facility and began to feel ill. The employee sustained dehydration due to heat.
An employee was pumping liquid propane from a propane delivery truck to a storage tank. After the transfer was completed, the employee closed the valves and disconnected the transfer hose. During the transfer, the liquid propane auto-refrigerated the riser pipe of the storage tank and that delayed the vaporization of the propane. Upon reaching a higher temperature, liquified propane began rapidly expanding. Liquid propane then discharged from the pipe and contacted the employee, causing cold burns. The employee was hospitalized for second-degree burns to their torso and arms.
An employee was moving a tensile strength test device with a dolly. The device fell from the dolly onto the employee's right leg, causing a compound fracture.
An employee was walking past a crossover conveyor when a ramp came down and hit them in the back. The employee sustained a broken back vertebra, as well as a concussion, and was hospitalized.
An employee was using a hook tool to pull a pallet onto the lift gate of a tractor trailer. The hook detached from the underside of the pallet, causing the employee to fall backward off the lift gate. The employee landed on the concrete parking lot about 5 feet below, suffering fractures to the skull and two thoracic vertebrae.
An employee was walking on a truss table when he lost his balance and fell approximately 3 feet to the floor. The employee sustained a dislocated and fractured left ankle.