Caught in or compressed by equipment or objects, unspecified · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at Brentwood Industries, Inc., 118 Brentwood Drive, HOPE, ARKANSAS 71801
on — Amputations, affecting the finger(s), fingernail(s), n.e.c..
Final narrative
An employee was helping another employee with a plastic roll on a line. A roll bar and its metal plate crushed the employee's left index finger, resulting in amputation of the finger.
An employee was preparing a roller machine for operation on a counter line. As they were rubbing the rollers with silicone, their hand got caught between two rollers, resulting in crush injuries.
An employee was changing mud cups in the hopper cylinders of a concrete pump truck. The cylinders moved and three of the employees fingers were amputated.
An employee was standing on the rig floor next to a polishing unit. His hand was placed on the polishing unit when the pump was lowered, resulting in amputation of their right thumb, ring, and middle fingertips.
An employee was using air to blow out the air wash to the blender and grinder station. As the employee reached to verify that the air wash was clean, the unit pinched and amputated their fingertip.
An employee was retrieving a lost drill pipe with a lifting bail when their left thumb got pinched between the table and handle of the lifting bail while trying to re-thread the pipe to lift it out. The employee suffered an amputation to the left thumb.
An employee was removing a core chuck from a stationary roll when their right ring finger was pinched between the chuck and the roll. The employee's fingertip was amputated.
More severe injuries in this industry (NAICS 326199)
An employee was operating a drill and tap machine. He was placing a part with his right hand and removing a part coming in on the left side. He saw a part that was crooked and went to straighten it. The machine clamped down on his left index finger, degloving the top part of the finger and resulting in a partial amputation.
An employee was performing maintenance on a roll cutting machine in a warehouse. The employee was removing excess grease from the bearings when the machine's chain caught their right index finger. The fingertip was amputated by the chain and sprocket.
During fiberglass work, an employee mixed a methyl ethyl ketone peroxide (MEKP) catalyst with a cobalt chemical that they thought was a dye. A chemical reaction occurred, resulting in an explosion. The employee sustained second-degree burns on his back and a blister on his right arm.
An employee was walking when she tripped over a box on the ground and fell. The employee was hospitalized with a severe dislocation to the hip and leg that required surgery.
An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.
On October 25, 2025, an employee was stringing up a new reel of tire tread on a machine. The employee pulled a 6-inch tail and proceeded to spool up the liner. As the machine was jogged to begin the liner wrapping process, the liner caught the employee's glove and pulled their right arm into the liner, causing a fracture to the arm.
An employee was doing a cable change on top of an electric overhead traveling (EOT) crane. They were positioned between the cable drum and the drive shaft. While rotating the cable drum, the employee reached for the new cable that was to be installed. The grease fitting on the drive shaft caught their fall harness and pulled them underneath the drive shaft. The employee was pinned between the drive shaft and two pieces of angle steel, resulting in a fracture to their left hip.
On October 5, 2025, an employee was pulling a pressure washer hose when it it disconnected from the cooker. The employee was struck by jets of high-pressure water, resulting in lacerations to their left thigh requiring surgery. The employee was hospitalized.