Indirect exposure to electricity, greater than 220 volts · Second degree electrical burns
At a glance
Federal OSHA recorded a severe workplace injury
at Jim Williams Fence Company, 1740 George Jenkins Blvd, LAKELAND, FLORIDA 33815
on — Second degree electrical burns, affecting the hand(s), unspecified.
Final narrative
An employee was in a manlift installing a 24-foot high chain link fence. One of the metal fence components that he was holding contacted a live power line, shocking the employee and causing second-degree burns to their left hand.
A crew was working near an electrical pole. A co-worker was using a front-loader to grade a slope when the loader slid into a guy-wire and became tangled and stuck. The injured employee used a handheld grinder to cut the wire a few feet from the ground. The lower part of the wire fell to the ground, but the upper part of the wire fell toward the pole and contacted an energized part before the end landed in nearby bushes. The employee attempted to shake the bush to free the wire so it could fall back toward the pole. The wire popped up and contacted his hands, resulting in electrical entry burns to both hands and exit burns on both feet.
On November 18, 2023, two employees were using a 2x4 to lift a power line. The boom lift they were operating made contact with power lines and both employees sustained electrical shock injuries.
An employee was part of a crew that was servicing a power line. The employee was in a bucket truck when he contacted the 7,200-volt power line. The electricity entered through one hand and exited the other, causing several electrical burns. The employee was not wearing proper personal protective equipment at the time.
An employee was helping a crew set up a 45-foot pole between two other poles. It was being set up between two energized lines and the pole made contact with the A-phase. The employee was electrocuted and lost consciousness. The electricity also caused an entry wound in their left forearm and an exit wound in their left foot.
An employee was handling a 45-foot long rebar for installation on the third floor of a building at a 30-foot elevation. The rebar came into close proximity of a powerline situated 13 feet off the building. The employee sustained electrical burns to his hands from electric discharge, requiring hospitalization.
More severe injuries in this industry (NAICS 236220)
The injured employee was standing behind a table. She jumped out to scare another employee, but tripped and fell on the tile floor, injuring her right ankle/foot. She was hospitalized with a dislocated ankle that required surgery.
An employee was installing insulation in a wall when she tripped on a hole (12" deep) and fell, hitting her head on the concrete floor. The employee sustained fractures to her leg and wrist, and lacerations to her head. The employee was hospitalized.
An employee was loading a 4-inch wooden door into a pickup truck when he felt a pop in his right side behind his shoulder blade. He was hospitalized later that day and underwent surgery, having suffered a collapsed right lung.
An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.
An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.
An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.
An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.