Performance Contractors, Inc.

Struck by swinging or slipping object, other than handheld, n.e.c. · Fractures

Federal OSHA recorded a severe workplace injury at Performance Contractors, Inc., 2357 LA-662, MORGAN CITY, LOUISIANA 70380 on — Fractures, affecting the hand(s), unspecified.

An employee was installing a horizontal steel beam that was being lowered by a crane. The beam lowered 4 inches and struck his left hand, causing fractures to the hand and injuries to the second digit below the knuckle.

Hospitalized Hand(s), unspecified Cranes, unspecified

Performance Contractors, Inc.

An employee was leaning down to install conduit. When he stood up, a 2-inch all-thread rod caught and lacerated his left eyelid.

Performance Contractors, Inc.

An employee was removing a 24" OD actuator valve that weighed 10,000 pounds from a structure on the fifth floor using a lattice crane. During the lift, the valve became hung up on the permanent handrail and their left thumb was caught between the valve and the handrail. The employee sustained a partial amputation of the thumb.

Performance Contractors Inc.

A crew was using a chain fall system to rig up a hard stop (metal structural support weighing 695 lbs.). The injured employee was guiding it into position. The hard stop shifted and their right hand was caught between the suspended hard stop and the adjacent structural wall, resulting in fractured ring and little fingers.

Performance Contractors Inc.

An employee was walking back from the tool room through the scaffolding material storage area. The employee's pant leg got caught on one of the 8-foot long scaffold planks that was in a scaffold rack. The employee tripped on the scaffold plank and fell forward, landing on his left elbow. The employee sustained a compound fracture to his left arm above the elbow and was hospitalized.

Performance Contractors, Inc.

A crew was using rope to move a 24" diameter blind flange from the receiving deck of elevation 4 to a lower location so it could be more easily accessed by a crane. The rope broke and the blind flange fell 15 inches to the receiving deck of elevation 3, landing on the injured employee's feet. Both feet were fractured.

View Performance Contractors, Inc.'s full OSHA safety record →

InterCon Construction, Inc.

A crew was pulling a 4-inch plastic gas pipe off a reel and straightening it for installation. The injured employee stepped up on the trailer to cut the last band holding the pipe in the coil on the reel. As he turned to step off the trailer, the end of the pipe rotated and sprung out of the cage surrounding the coil, striking the employee on the side of the head and knocking him off of the trailer into the roadway. The employee suffered head trauma that required hospitalization.

RAVA Construction, LLC

An employee and a co-worker were performing a pick inside a clear well. They rigged the skid pan that was full of broken concrete. When lifting, the load began to swing toward a wall. The employee tried to stop the skid pan from swinging and was struck by the pan, resulting in fractures to their left hip and wrist.

Stein, LLC

The employee had just completed refueling a lattice crane that was breaking up material and was winding the fuel hose back into the fuel truck when he was struck by the catwalk/stairs of the crane. The employee was hospitalized with a laceration to his backside, possible internal bleeding, and a broken hip.

7 Site & Utility, LLC

An employee was fusing 10-inch black rubber utility pipes together using a pipe fusion machine and could not get the pipes to set correctly. The employee used a nylon strap attached to an excavator to lift one side of a pipe off a steel plate. As his hand was between two pipes, the pipes came back together, partially amputating two of his fingers.

Sterling Steel Company, LLC

An employee was lifting four bags of a lime blend weighing approximately 10,000 pounds using a crane. The load swung and pinned the employee against a structural I-beam, resulting in fractures to the hip and pelvis.

Bowman Energy Services LLC

An employee was acting as a spotter for a forklift operator. While its forks were being raised, the forklift came into contact with a power line. The employee was touching the forklift's metal frame at the time and was shocked on the left palm. The employee suffered burns to both the left palm and the sole of the left foot.

Performance Contractors, Inc.

An employee was leaning down to install conduit. When he stood up, a 2-inch all-thread rod caught and lacerated his left eyelid.

Integrated Service Company LLC

An employee was working as a fire watch. The employee was exposed to anhydrous ammonia and was not able to see while climbing down a ladder due to eye irritation. The employee fell and was hospitalized for a broken ankle.

Puris Corporation

An employee was standing on the ground awaiting the lowering of a pipe. After the pipe was lowered to the ground by a skid steer, it rolled and struck the employee's left leg. The employee was hospitalized with a fractured leg.

Precision Petroleum Inc

An employee was tightening a gas pipe with a wrench when the wrench slipped from his hand. The employee's arm then hit a metal cross-brace, resulting in a lacerated arm.

Kisatchie Midnight Express

A driver was exiting his vehicle outside the plant gate when his foot slipped on the top step of the truck. He fell to the ground, landed on his left hip and elbow. The employee was hospitalized with a fractured hip/femur.

CHRISTUS St. Frances Cabrini Hospital

A security employee was responding to an urgent call from staff regarding a violent patient. The employee tripped and fell on the floor outside of the stairwell. The employee sustained a closed head injury, contusion of the cerebrum without loss of consciousness, and a closed fracture of the distal end of the right radius.

Jean Simpson Personnel Services, Inc.

A temporary employee was testing an electrical starter motor. He was placing tape on the starter while the breaker was not engaged, but the starter sent an arc flash that burned his hands and stomach.

Calvary Industries Inc

An employee was walking on a sidewalk and stubbed his toe on an elevated portion of concrete, causing him to trip and fall. The employee's right knee was dislocated.