Ignition of vapors, gases, or liquids · Heat (thermal) burns, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Miller Pipeline, LLC, 2637 Alexander Rd, ATWATER, OHIO 44201
on — Heat (thermal) burns, unspecified, affecting the multiple body parts, n.e.c..
Final narrative
On August 24, 2023, a crew was removing a natural gas regulator station. Oil became heated and sprayed onto an employee causing a flash fire. The employee was hospitalized for burns to the back, neck, and arms.
HospitalizedMultiple body parts, n.e.c.Coal, natural gas, petroleum fuels and products, unspecified
A crew was installing a pistol (electrical connection) to a new section of underground electric cable. The injured employee went to align the cable and pistol and it contacted a live bushing instead of the grounded bushing. An arc flash occurred. The employee sustained second-degree electrical burns to his left forearm and right hand, index finger, and thumb. The employee was hospitalized.
An employee was placing an 8-inch pipe fitting into a toolbox. The fitting slipped and caught the employee's finger against other items in the box. The employee sustained a fingertip amputation.
An employee was turning a pipe with a pipe wrench when the wrench slipped, pinching the employee's left index finger between the wrench and pipe resulting in amputation at the first joint.
Through the morning hours an employee was operating a hydro-excavator to spot utilities. The employee later took a break under a tree and lost consciousness. The employee was hospitalized with heat exhaustion and dehydration.
An employee was cleaning a cordless drill. As they applied brake fluid to the drill and pulled the trigger, the fluid ignited. The employee suffered burns to the face, hands, and arms.
An employee was spraying glue to the floor of an enclosed cargo trailer. The fumes made contact with the heater causing a flash fire. The employee suffered burns to their face and right hand.
An employee was replacing a valve in the gas line to the fryer. The shutoff valve malfunctioned resulting in a gas leak that then ignited. The employee sustained burns requiring hospitalization.
An employee was acting as a spotter for a forklift operator. While its forks were being raised, the forklift came into contact with a power line. The employee was touching the forklift's metal frame at the time and was shocked on the left palm. The employee suffered burns to both the left palm and the sole of the left foot.
An employee was working as a fire watch. The employee was exposed to anhydrous ammonia and was not able to see while climbing down a ladder due to eye irritation. The employee fell and was hospitalized for a broken ankle.
An employee was standing on the ground awaiting the lowering of a pipe. After the pipe was lowered to the ground by a skid steer, it rolled and struck the employee's left leg. The employee was hospitalized with a fractured leg.
An employee was tightening a gas pipe with a wrench when the wrench slipped from his hand. The employee's arm then hit a metal cross-brace, resulting in a lacerated arm.
An employee was working to deliver mail to an apartment building. She was waiting for a customer to move, to obtain clearance to the mailboxes. The door swung inward and closed on her right little finger. The top half of her finger was surgically amputated.
An employee fell from a step ladder while reaching for a tie-off point. He impacted the ground, and landed on his bolt bag which contained tools. The employee was hospitalized with fractured ribs, and a lacerated spleen and kidney.
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was moving a scissor lift through a doorway. The employee was pinned between the scissor lift and the doorframe, sustained a back injury, and was hospitalized.
An employee was setting up communication equipment for a meeting. They were walking and tripped over a speaker on the ground. The employee sustained a leg injury.