105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

CBRE Inc.

Other fall to lower level less than 6 feet · Fractures

Federal OSHA recorded a severe workplace injury at CBRE Inc., 1544 Valwood Parkway, CARROLLTON, TEXAS 75006 on — Fractures, affecting the chest, except internal location of diseases or disorders.

An employee was on an A-frame ladder changing lights when they fell from the third step, resulting in rib fractures.

Hospitalized Chest, except internal location of diseases or disorders Step ladders

CBRE, Inc.

An employee was troubleshooting an electrical panel when an arc flash occurred and the employee lost consciousness. The employee also sustained burns and was hospitalized.

CBRE, Inc.

An employee was walking at ground level toward a manhole, carrying a manhole removal device. The employee tripped and fell onto the manhole removal device, resulting in multiple fractured ribs and a punctured lung.

CBRE Inc

An employee was using a 71.3-pound jackhammer to break up a concrete pad. The jackhammer became stuck in the concrete. The employee tried to pull the jackhammer out of the concrete and sustained a hernia requiring hospitalization and surgery.

CBRE Inc.

An employee was ascending a ladder to access wiring on top of a chiller unit when they fell to the ground. The employee sustained internal bleeding near their hip and a broken rib.

CBRE Inc.

An employee was walking down the stairs when she lost her footing and fell down the stairs. The employee scraped both hands and her left knee, and struck a door at the bottom of the staircase.

View CBRE Inc.'s full OSHA safety record →

Electrical Contractors Inc.

An employee was climbing a step ladder while carrying a 3-foot piece of conduit. As he went to reposition his feet on the ladder by pivoting, he slipped and fell from the third rung of a 6-foot ladder. The employee sustained fractures to the left femur, right elbow, and right ring finger.

M1 Support Services

An employee was descending a 4-step maintenance stand when she missed the bottom step and fell to the hangar floor. The employee suffered a left hip fracture.

FEDEX Ground Package System, Inc.

An employee stopped a belt and was going to check it for missing packages. She fell backward 3-4 feet from an elevated platform and sustained a broken right arm.

SRM Concrete

An employee had just finished a routine concrete pour and was ascending the ladder to clean the concrete mixer truck. The employee lost their grip and fell approximately 2-3 feet, contacting the truck's bumper. The employee suffered rib fractures and a punctured lung.

U.S. Postal Service - Los Angeles P&DC

An employee was performing duties as an expeditor. After opening the dock door, the employee scanned the barcode on the door of the truck and placed one foot on the truck and one foot on the dock. The truck drove out of the stall, causing the employee to fall 4 feet off the dock onto the concrete. The employee sustained fractures to the right side of the pelvis, elbow, and a left ring fingertip as well as injuries to the right wrist and bruising to the back and stomach.

NATIONAL MILL MAINTENANCE, LLC

An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.

Elkhorn Mechanical and Combustion

An employee was climbing a ladder to inspect a vent in a restaurant dining area. The ladder slid out on the floor and the employee fell approximately 12 feet onto the ladder and the floor. He was hospitalized with a dislocated shoulder and a back injury.

Crown Lift Trucks

An employee was operating a lift truck when it struck a stationary lift truck. His left thumb was pinched between the two lift trucks, resulting in a partial amputation.

Spellman High Voltage Electronics Corporation - Valhalla

An employee was disassembling a pressurized unit using a driver drill. When the unit was disassembled, it caused a kickback from the tube head, causing the drill to strike the employee's left forearm. They sustained a diaphyseal fracture to their left radius and ulna, which required surgery.

Ring Power Corporation

After repairing a piece of industrial equipment, an employee had brake-cleaning liquid on his gloves. A lighter ignited the liquid, and the employee's hands were severely burned.

T G Meat Center LLC

After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.

Professional Flooring Supply

An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.

EnviroSafe Demil LLC

An employee was inspecting flares processes. The employee received burns to the front side of the body, face and arm from the flares.

Inteplast Group

An employee was removing plastic material from a production line when the machine cycled and amputated his left index, ring, and little fingers.

Regency IHS of Fairwinds Halletsville, LLC

An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.