Ignition of vapors, gases, or liquids · Heat (thermal) burns, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at CVR Common Services, LLC, 400 N LINDEN ST, COFFEYVILLE, KANSAS 67337
on — Heat (thermal) burns, unspecified, affecting the multiple body parts, n.e.c..
Final narrative
An employee was removing bolts from a pipe flange in order to remove an isolation blind. The employee was pulling the blind from the piping system when hydrogen gas released and flashed, resulting in burns to their face and left wrist.
An employee was cleaning a cordless drill. As they applied brake fluid to the drill and pulled the trigger, the fluid ignited. The employee suffered burns to the face, hands, and arms.
An employee was spraying glue to the floor of an enclosed cargo trailer. The fumes made contact with the heater causing a flash fire. The employee suffered burns to their face and right hand.
An employee was replacing a valve in the gas line to the fryer. The shutoff valve malfunctioned resulting in a gas leak that then ignited. The employee sustained burns requiring hospitalization.
An employee was ascending an 8-foot aluminum extension ladder to access and replace a hypochlorite pump located on top of a 7-foot chemical tank. When he reached approximately 5 feet on the ladder, the ladder shifted and twisted to the right. The employee fell from the ladder and landed on his right side. The employee sustained a compound fracture to his right leg just above the ankle, dislocation of his shoulder, and a torn rotator cuff. The employee was hospitalized.
An employee was taking a butane gas sample as part of the hydrocarbon refining process. A component disconnected and the butane ignited, resulting in first- and second-degree burns to the employee's forearms and to their face, including their cheeks, chin, and neck.
An employee was driving a carry deck/small crane when its boom made contact with an overhead support beam. The employee was jostled in the cab and suffered a concussion.
An employee was inventorying hammer mill screens when the screens fell on the employee. The employee sustained a laceration to their leg requiring hospitalization.
An ironworker was maneuvering a mobile elevated work platform (MEWP) into position to install a structural beam. The employee was pinned between another structural steel beam that was already installed and the MEWP control box cover. The employee was hospitalized with a laceration to their lip, dislodged teeth, and a fractured jaw.
An employee was working to remove a product blockage from a piece of equipment. The employee was struck by a metal bar near the deck of the pin mixer equipment and sustained blunt force trauma to the torso.
An employee was moving a rack onto a lower conveyor in the south heat treat area when their finger got caught between the part tray and the rollers, resulting in a fingertip fracture and amputation.
An employee was climbing a ladder to get on top of the breakroom. The ladder slipped, causing him to fall to the ground. The employee sustained fractures to his upper back, left foot, and ankle.
Two employees were removing a circuit breaker. The injured employee was using wrenches in the removal process. One of the wrenches contacted an adjacent door, resulting in an arc flash. The employee suffered burns to their neck, face, and ear, as well as momentary vision loss due to the flash.
An employee bent over to pick up a rubber mat from the ground. When he grabbed the corner of the mat, a rattlesnake hidden under it bit his left middle finger near the first knuckle. He was hospitalized.